4.6 Article

Investigation on Reduction of Pressure Fluctuation for a Double-Suction Centrifugal Pump

期刊

出版社

SPRINGER
DOI: 10.1186/s10033-020-00505-8

关键词

Double-suction centrifugal pump; Pressure fluctuation; Flow uniformity; Numerical simulation

资金

  1. National Natural Science Foundation of China [52076186, 51839010]

向作者/读者索取更多资源

The study redesigned a double-suction centrifugal pump with high vibration and noise demands by increasing flow uniformity at the impeller discharge through combinations of multiple parameters. The results showed a significant reduction in pressure fluctuations by increasing the number of impeller blades, radial gap, and optimizing the staggered arrangement. The redesigned pump demonstrated a substantial decrease in pressure fluctuation intensity, indicating the effectiveness of the modifications in reducing pressure fluctuations.
Double-suction centrifugal pumps have been applied extensively in many areas, and the significance of pressure fluctuations inside these pumps with large power is becoming increasingly important. In this study, a double-suction centrifugal pump with a high-demand for vibration and noise was redesigned by increasing the flow uniformity at the impeller discharge, implemented by combinations of more than two parameters. First, increasing the number of the impeller blades was intended to enhance the bounding effect that the blades imposed on the fluid. Subsequently, increasing the radial gap between the impeller and volute was applied to reduce the rotor-stator interaction. Finally, the staggered arrangement was optimized to weaken the efficacy of the interference superposition. Based on numerical simulation, the steady and unsteady characteristics of the pump models were calculated. From the fluctuation analysis in the frequency domain, the dimensionless pressure fluctuation amplitude at the blade passing frequency and its harmonics, located on the monitoring points in the redesigned pumps (both with larger radial gap), are reduced a lot. Further, in the volute of the model with new impellers staggered at 12 degrees, the average value for the dimensionless pressure fluctuation amplitude decreases to 6% of that in prototype pump. The dimensionless root-mean-square pressure contour on the mid-span of the impeller tends to be more uniform in the redesigned models (both with larger radial gap); similarly, the pressure contour on the mid-section of the volute presents good uniformity in these models, which in turn demonstrating a reduction in the pressure fluctuation intensity. The results reveal the mechanism of pressure fluctuation reduction in a double-suction centrifugal pump, and the results of this study could provide a reference for pressure fluctuation reduction and vibration performance reinforcement of double-suction centrifugal pumps and other pumps.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据