Arsenic removal from groundwater using an aerated electrocoagulation reactor with 3D Al electrodes in the presence of anions

期刊

CHEMOSPHERE
卷 263, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.chemosphere.2020.128253

关键词

Arsenic removal; Anions; Aerated electrocoagulation; 3D Al ball Electrodes; Groundwater

资金

  1. TUBITAK (The Scientific and Technical Research Council of Turkey) [111Y103]

向作者/读者索取更多资源

This study investigated the combined effects of anions on arsenic removal in groundwater using aerated electrocoagulation technology. Optimal operating parameters were determined through experimental design and mathematical modeling, revealing the relationship between independent parameters and treatment efficiency.
Co-occurrence of arsenic and anions in groundwater causes a severe health problems and combine effects of these pollutants significantly affect performance of treatment process. Thus, this study has been conducted to examine the combine effects of anions on arsenic removal using aerated electrocoagulation (EC) reactor with 3D Al electrodes in groundwater. A 3-level, six factors Box-Behnken experimental design (BBD) was applied to investigate the individual and combine effect of anions and operating time: phosphate (x(1): 1-10 mg L-1), silica (x(2): 20-80 mg L-1), bicarbonate (x(3): 130-670 mg L-1), fluoride (x(4): 2-10 mg L-1), boron (x(5): 5-10 mg L-1), and operating time (x(6): 8-22 min) on desired responses. The specified responses were effluent arsenic concentration (C-f,C-As), removal efficiency of arsenic (R-e), consumptions of energy and electrode (ENC and ELC), operational cost (OC), and adsorption capacity (q(e)). The optimum operating parameters predicted using BBD were found to be x(1): 1.0 mg L-1, x(2): 26.0 mg L-1, x(3): 651.5 mg L-1, x(4): 2.0 mg L-1, x(5): 9.9 mg L-1, and x(6): 10.5 min considering highest removal efficiency of arsenic and lowest operational cost. Under these operating conditions, the experimental values of C-f,C-As, R-e, ENC, ELC, OC, and q(e) were found to be 2.82 mu g L-1, 98.6%, 0.411 kWh m(-3), 0.0124 kg m(-3), 0.098 $ m(-3), and 17.65 mu g As (mg Al)(-1), respectively. Furthermore, mathematical modelling was conducted using quadratic regression model and response surface analysis was performed to understand the relationship between independent parameters and responses. (C) 2020 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据