4.7 Article

Impacts of using auto-mode portable air cleaner on indoor PM2.5 levels: An intervention study

期刊

BUILDING AND ENVIRONMENT
卷 188, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.buildenv.2020.107444

关键词

Auto mode; Portable air cleaner (PAC); PM2.5; Indoor air quality (IAQ); Cooking; Linear mixed-effects regression (LMER)

资金

  1. University of Washington Environmental Health Research Experience Program (EHREP)
  2. National Institutes of Environmental Health Science (NIEHS) [5P30 ES007033]
  3. NIEHS [R33 ES024715]

向作者/读者索取更多资源

The study suggests that using auto-mode portable air cleaners can significantly reduce indoor PM2.5 levels in households, especially during cooking events, making it a practical and effective method for indoor air quality improvement.
Auto-mode portable air cleaners (PACs) designed to turn on automatically in response to elevated indoor PM2.5 concentrations are widely used in residences. This study assesses the impacts of using such PACs equipped with high-efficiency particulate air filters on residential PM2.5 levels in six households recruited in Seattle, Washington, for a randomized crossover study, in which participants used a PAC in their homes under three intervention scenarios: (1) sham-mode filtration in which all filters in the PAC were removed, (2) auto-mode filtration in which the PAC was set to auto mode, and (3) adjustable-mode filtration in which the participants were allowed to manually adjusted the PACs. Each filtration session was one-week long. PM2.5 levels were measured at 1-min intervals in the kitchen and living room of each household. Also, an hourly time-activity log was collected from each participant. The empirical concentrations and I/O ratios of PM2.5 were compared among the three filtration modes. Additionally, linear mixed-effects regression models (LMER) were developed to reveal the impacts of different filtration modes on indoor PM2.5, while controlling for outdoor PM2.5, indoor cooking events, and indoor relative humidity, and temperature. Based on the LMER models, when indoor cooking events were present and absent, auto-mode filtration significantly reduced the indoor PM2.5 levels by 31% [95% CI: 19%, 42%] and 28% [95% CI: 22%, 34%], respectively, compared with sham-mode filtration, and reduced the indoor PM2.5 levels by 19% [95% CI: 6%, 31%] and 4% [95% CI: 4%, 11%], respectively, compared with adjustable-mode filtration. These findings suggest that using such PACs running in auto mode is a practical and effective way to reduce indoor PM2.5 levels.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据