4.8 Article

Energy planning of renewable applications in high-rise residential buildings integrating battery and hydrogen vehicle storage

期刊

APPLIED ENERGY
卷 281, 期 -, 页码 -

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.apenergy.2020.116038

关键词

Solar photovoltaic; Wind turbine; Battery storage; Hydrogen vehicle; High-rise building; Energy planning

资金

  1. National Key R&D Program of China: Research and integrated demonstration on suitable technology of net zero energy building [2019YFE0100300]
  2. Australian Research Council DECRA Fellowship [DE200101597]
  3. Hong Kong Polytechnic University [1-ZE8B]
  4. Australian Research Council [DE200101597] Funding Source: Australian Research Council

向作者/读者索取更多资源

This study proposed a robust energy planning approach for hybrid photovoltaic and wind energy systems in high-rise residential buildings. Results indicated that different energy management strategies can achieve optimal performance in hybrid systems with large installation capacities. The final optimum solutions showed positive environmental impacts with negative carbon emissions.
This study presents a robust energy planning approach for hybrid photovoltaic and wind energy systems with battery and hydrogen vehicle storage technologies in a typical high-rise residential building considering different vehicle-to-building schedules. Multiple design criteria including the supply performance, grid integration and lifetime net present value are adopted to size the hybrid system and select the optimal energy management strategy. Four decision-making strategies are further applied to search the final optimum solution for major stakeholders with different preferences. The study result indicates that the energy management strategy with battery storage prior to hydrogen storage is suitable for hybrid systems with large photovoltaic, wind and battery installation capacities to achieve the optimum supply-grid integration-economy performance. The energy management strategy with hydrogen storage prior to battery storage has a wider applicability, and this strategy should be selected when focusing on the supply-grid integration or supply-economy performance. The annual average self-consumption ratio, load cover ratio and hydrogen system efficiency are about 84.79%, 76.11% and 77.06% respectively in the end-user priority case. The annual absolute net grid exchange is about 4.55 MWh in the transmission system operator priority case. The lifetime net present value of the investor priority case is about 3.64 million US$, 29.88% less than the equivalent priority case. Final optimum solutions show positive environmental impacts with negative annual carbon emissions. Such a techno-economic-environmental feasibility analysis of the hybrid system provides major stakeholders with valuable energy planning references to promote renewable applications in urban areas.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据