This study introduces an innovative device for noninvasive sampling and chromatographic analysis of compounds in exhaled breath aerosol, combining the advantages of FPSM sampling device with LC-MS/MS screening procedure. The approach allows for rapid screening analyses for human exposure to different compounds, providing a powerful and green tool.
This study introduces an innovative device for the noninvasive sampling and chromatographic analysis of different compounds present in exhaled breath aerosol (EBA). The new sampling device, especially in light of the recent COVID-19 pandemic that forced many countries to impose mandatory facemasks, allows an easy monitoring of the subject's exposure to different compounds they may come in contact with, actively or passively. The project combines the advantages of a fabric-phase sorptive membrane (FPSM) as an in vivo sampling device with a validated LC-MS/MS screening procedure able to monitor more than 739 chemicals with an overall analysis time of 18 min. The project involves the noninvasive in vivo sampling of the EBA using an FPSM array inserted inside an FFP2 mask. The study involved 15 healthy volunteers, and no restrictions were imposed during or prior to the sampling process regarding the consumption of drinks, food, or drugs. The FPSM array-LC-MS/MS approach allowed us to effectively exploit the advantages of the two complementary procedures (the convenient sampling by an FPSM array and the rapid analysis by LC-MS/MS), obtaining a powerful and green tool to carry out rapid screening analyses for human exposure to different compounds. The flexible fabric substrate, the sponge-like porous architecture of the high-efficiency sol-gel sorbent coating, the availability of a large cache of sorbent coatings, including polar, nonpolar, mixed mode, and zwitterionic phases, the easy installation into the facemask, and the possibility of sampling without interrupting regular activities provide FPSMs unparalleled advantages over other sampling techniques, and their applications are expected to expand to many other clinical or toxicological studies.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据