4.7 Article

High-throughput hydrogen deuterium exchange mass spectrometry (HDX-MS) coupled with subzero-temperature ultrahigh pressure liquid chromatography (UPLC) separation for complex sample analysis

期刊

ANALYTICA CHIMICA ACTA
卷 1143, 期 -, 页码 65-72

出版社

ELSEVIER
DOI: 10.1016/j.aca.2020.11.022

关键词

HDX-MS; UPLC separation; Proteomics; High-throughput; Sub-zero temperature

资金

  1. NIH NIAID [R01 AI41625]
  2. NIH [NIH/NIAID-2U19AI062629]

向作者/读者索取更多资源

HDX-MS is a powerful technique for studying protein dynamics and interactions, with recent technological advancements allowing for its application in analyzing complex protein samples. Optimized long gradient subzero-temperature UPLC separation conditions identified a large number of deuterated peptides in E. coli cell lysate digest.
Hydrogen deuterium exchange coupled with mass spectrometry (HDX-MS) is a powerful technique for the characterization of protein dynamics and protein interactions. Recent technological developments in the HDX-MS field, such as sub-zero LC separations, large-scale data analysis tools, and efficient protein digestion methods, have allowed for the application of HDX-MS to the analysis of multi protein systems in addition to pure protein analysis. Still, high-throughput HDX-MS analysis of complex samples is not widespread because the co-elution of peptides combined with increased peak complexity after labeling makes peak de-convolution extremely difficult. Here, for the first time, we evaluated and optimized long gradient subzero-temperature ultra-high-pressure liquid chromatography (UPLC) separation conditions for the HDX-MS analysis of complex protein samples such as E. coli. cell lysate digest. Under the optimized conditions, we identified 1419 deuterated peptides from 320 proteins at -10 degrees C, which is about 3-fold more when compared with a 15-min gradient separation under the same conditions. Interestingly, our results suggested that the peptides eluted late in the gradient are well-protected by peptide-column interactions at -10 degrees C so that peptides eluted even at the end of the gradient maintain high levels of deuteration. Overall, our study suggests that the optimized, sub-zero, long-gradient UPLC separation is capable of characterizing thousands of peptides in a single HDX-MS analysis with low back-exchange rates. As a result, this technique holds great potential for characterizing complex samples such as cell lysates using HDX-MS. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据