4.4 Article

Angiotensin Receptor Blockers in cyclodextrin nanoparticle eye drops: Ocular pharmacokinetics and pharmacologic effect on intraocular pressure

期刊

ACTA OPHTHALMOLOGICA
卷 99, 期 4, 页码 376-382

出版社

WILEY
DOI: 10.1111/aos.14639

关键词

angiotensin receptor blockers; glaucoma; intraocular pressure; pharmacokinetics

资金

  1. European Union's programme Eurostar [PREVIN E11008]
  2. European Union's Horizon 2020 research and innovation programme under the Marie Sklodowska-Curie grant [765441]
  3. Marie Curie Actions (MSCA) [765441] Funding Source: Marie Curie Actions (MSCA)

向作者/读者索取更多资源

The study found that nanoparticle eye drops containing ARBs effectively reduced intraocular pressure in rabbits and showed potential for delivering drug concentrations to intraocular tissues.
Purpose Orally administered angiotensin II receptor blockers (ARBs) decrease intraocular pressure (IOP). Topical administration may reduce systemic side effects and result in a useful glaucoma drug. The aim of this study is to test the ocular delivery and pharmacologic effect of nanoparticle eye drops containing ARBs (e.g. irbesartan and candesartan). Methods 1.5% irbesartan and 0.15% candesartan eye drops were applied to rabbits. The pharmacokinetics in cornea and aqueous humour after single eye drop application were studied in 49 rabbits. The effect of the eye drops on IOP was studied in 10 rabbits using an iCare ((R) TonoVet Plus, iCare, Finland) tonometer and compared with 0.5% timolol eye drops. Results Candesartan lowered IOP from 24.6 +/- 5.1 mmHg at baseline to 19.0 +/- 2.9 mmHg (mean +/- SD, p = 0.030, n = 10) 4 hr after application. Irbesartan lowered IOP from 24.2 +/- 1.7 mmHg to 20.2 +/- 0.9 mmHg (p = 0.14, n = 10). Timolol decreased the IOP from 24.9 +/- 4.2 mmHg to 20.4 +/- 4.8 mmHg (mean +/- SD, p = 0.036, n = 10). The pharmacokinetics data show that both formulations deliver effective amounts of drug into the intraocular tissues, with irbesartan and candesartan reaching concentrations of 121 +/- 69 and 30.43 +/- 13.93 ng/g (mean +/- SD), respectively, in the aqueous humour 3 hr after a single-dose administration. Conclusions Topical application of irbesartan and candesartan eye drops delivers effective drug concentrations to the anterior segment of the eye in rabbits, achieving drug concentrations 100 times above the IC50 for angiotensin II receptor and showing an IOP-lowering effect. Angiotensin receptor blocker (ARB) eye drops have potential as a new class of glaucoma drugs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据