4.8 Article

Hydrogen-Bond-Triggered Hybrid Nanofibrous Membrane-Based Wearable Pressure Sensor with Ultrahigh Sensitivity over a Broad Pressure Range

期刊

ACS NANO
卷 15, 期 3, 页码 4380-4393

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsnano.0c07847

关键词

MXene; lithium sulfonamides; ionic nanofibrous membrane; capacitive pressure sensor; e-skin; wearable medical device

资金

  1. Ministry of Trade, Industry & Energy (MI, Korea) [20000773]
  2. Bio & Medical Technology Development Program of the NRF - Korean government (MSIT) [NRF-2017M3A9F1031270]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [20000773] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)
  4. National Research Foundation of Korea [4299990114056] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

A novel method involving a hybrid ionic nanofibrous membrane sensing layer was proposed to enhance the sensitivity and linearity range of a capacitive pressure sensor. The sensor exhibited high sensitivity, short response time, and excellent durability, making it potentially useful for mobile medical monitoring devices and next-generation artificial e-skin.
Recently, flexible capacitive pressure sensors have received significant attention in the field of wearable electronics. The high sensitivity over a wide linear range combined with long-term durability is a critical requirement for the fabrication of reliable pressure sensors for versatile applications. Herein, we propose a special approach to enhance the sensitivity and linearity range of a capacitive pressure sensor by fabricating a hybrid ionic nanofibrous membrane as a sensing layer composed of Ti3C2Tx MXene and an ionic salt of lithium sulfonamides in a poly(vinyl alcohol) elastomer matrix. The reversible ion pumping triggered by a hydrogen bond in the hybrid sensing layer leads to high sensitivities of 5.5 and 1.5 kPa(-1) in the wide linear ranges of 0-30 and 30-250 kPa, respectively, and a fast response time of 70.4 ms. In addition, the fabricated sensor exhibits a minimum detection limit of 2 Pa and high durability over 20 000 continuous cycles even under a high pressure of 45 kPa. These results indicate that the proposed sensor can be potentially used in mobile medical monitoring devices and next-generation artificial e-skin.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据