4.7 Article

Inclined forward osmosis module system for fouling control in sustainable produced water treatment using seawater as draw solution

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jwpe.2020.101752

关键词

Forward osmosis; Produced water treatment; Fouling control; Air sparging; Inclined membrane module

资金

  1. Yayasan Universiti Teknologi PETRONAS [0153AA-E96]
  2. HiCOE AMTEC [A.J090301.5300.07092]

向作者/读者索取更多资源

The study focused on fouling control in a forward osmosis system for concentrating produced water by using seawater as a draw solution. Multi-stage concentration with aeration and module inclination showed higher fluxes and concentration factor compared to single-stage concentration. Aeration effectively improved water flux and suppressed fouling, especially when the filtration cell was inclined at a certain angle.
Produced water (PW) generated from oil and gas production is a threat to the environment if not treated properly. Conventional methods for PW treatment are often accompanied by a series of treatments to fulfill the discharge standard. Forward osmosis (FO) is a promising option due to its high solute retention, less irreversible fouling, low energy footprint and potentially used as a standalone unit. However, FO still suffers from the low flux and fouling when treating highly contaminated feeds. This study investigated fouling control in the FO system for concentrating PW by using seawater as a draw solution (DS). A multi-stage filtration system (via via replenishments of the DS) with an aeration and module inclination for fouling mitigation was proposed to improve concentration factor (CF) and flux. Results showed that the multi-stage concentration offered higher fluxes range of 1.72-15.48-1.72 L/(m(2)h) (LMH) and four times of CF than the single-stage one with fluxes range of 0.39-9.49 LMH corresponding to CF of 1.75. The aeration was effective to enhance the water flux and suppress the fouling, and showed a significant impact at the rate of 0.4 L/min, reaching flux increment by 11 times at a rate of 1 L/min. The impact of aeration was enhanced by inclining the filtration cell up to 5 times at the inclination angle (0) of 90 degrees due to the improved contacts of air bubbles with the membrane surface. The contribution of the aeration and cell inclination on the water flux can be explained through the forces acting on moving air bubbles.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据