4.5 Article

Novel metal mesh filter using water-based regeneration for small-scale biomass boilers

期刊

BIOMASS CONVERSION AND BIOREFINERY
卷 12, 期 8, 页码 3183-3195

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s13399-020-00959-9

关键词

Biomass combustion; Particulate matter; Particulate matter filter; Ultrasound cleaning; Emission control; Baghouse filter; Ultrafine dust

资金

  1. Projekt DEAL
  2. Fachagentur Nachwachsende Rohstoffe (FNR) [22019417]

向作者/读者索取更多资源

This study developed and tested a novel gas cleaning method using a metal mesh filter combined with water-based cleaning to reduce particulate matter emissions from biomass boilers. The results showed that metal mesh filters with countercurrent cleaning have a high potential for commercial application due to their simple and robust design, as well as high collection efficiency.
Particulate matter emissions are a key issue of modern biomass boilers. A novel gas cleaning method using a metal mesh filter combined with water-based cleaning was developed and tested. The filter was tested batch-wise. Flue gas of a commercial 50-kW boiler was filtered until a pressure drop of 2000 Pa was reached. Afterwards, the filter was regenerated. The initial prototype used ultrasound in order to remove the filter cake from the filter candles. Regeneration was complete and, even after boiler malfunctions producing tar, the filter cake could still be removed. Given the good results, a second cleaning mode, flushing the filter candles with water, was tested. The results were as good as with ultrasonic cleaning. Peak mass collection efficiency was very high with 98 +/- 2% (burning wood pellets). However, directly after cleaning, the first layer of filter cake has to be developed. In this initial phase, collection efficiency is low. Service time until maximum pressure drop was reached depended on the gas velocity. Using pellets as fuel, at a gas velocity of 66.6 m/h, 12-h service time was reached and 4.1 g dust was collected per square meter filter surface, while at 33.3 m/h, service time increased to 55 h and collected dust to 13.9 g/m(2). Using low-quality wood chips, the raw gas dust loading was much higher but also the maximum loading of the filter was higher with 13.3 to 28.9 g dust separated per square meter. Still, the service time decreased to 3.4 respective 38 h. Peak collection efficiency increased to 99.5 +/- 0.8%. The overall collection efficiency including the buildup of the filter cake depends on the gas velocity and fuel. It ranges from 74 +/- 4 to 91 +/- 1%. The feasibility of the filter concept could be proven, and further development towards a commercial application is in progress. Metal mesh filters with countercurrent cleaning showed a high potential given their simple and robust design, as well as high collection efficiency.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据