4.5 Article

Feasibility and reproducibility of a cardiovascular magnetic resonance free-breathing, multi-shot, navigated image acquisition technique for ventricular volume quantification during continuous exercise

期刊

出版社

AME PUBL CO
DOI: 10.21037/qims-20-117

关键词

Cardiovascular magnetic resonance (CMR); exercise; magnetic resonance imaging ergometer (MRI ergometer); free-breathing; feasibility; respiratory-navigation

资金

  1. National Institute for Health Research (NIHR) infrastructure at Leeds

向作者/读者索取更多资源

Background: Cardiovascular magnetic resonance (CMR) image acquisition techniques during exercise typically requires either transient cessation of exercise or complex post-processing, potentially compromising clinical utility. We evaluated the feasibility and reproducibility of a navigated image acquisition method for ventricular volumes assessment during continuous physical exercise. Methods: Ten healthy volunteers underwent supine cycle ergometer (Lode) exercise CMR on two separate occasions using a free-breathing, multi-shot, navigated, balanced steady-state free precession cine pulse sequence. Images were acquired at 3- stages, baseline and during steady-state exercise at 55% and 75% maximal heart rate (HRmax), based on a prior supine cardiopulmonary exercise test. Intra-and inter-observer variability and inter-scan reproducibility were derived. Clinical feasibility was tested in a separate cohort of patients with severe mitral regurgitation (n=6). Results: End-diastolic volume (EDV) of both LV and RV decreased during exercise at 55% and 75% HRmax, although a reduction in RVEDV index was only observed at 75% HRmax. Ejection fractions (EF) for both ventricles were significantly higher at 75% HRmax compared to their respective baselines (LVEF 68%+/- 3% vs. 58%+/- 5%, P=0.001; RVEF 66%+/- 4% vs. 58%+/- 7%, P=0.02). Intra-observer and inter-observer reproducibility of LV parameters was excellent at all 3-stages. Although measurements of RVESV were more variable during exercise, the reproducibility of both RVEF and RV cardiac index was excellent (CV <10%). Inter-scan LV and RV ejection fraction were highly reproducible at all 3 stages, although inter-scan reproducibility of indexed RVESV was only moderate. The protocol was well tolerated by all patients. Conclusions: Exercise CMR using a free-breathing, multi-shot, navigated cine imaging method allows simultaneous assessment of left and right ventricular volumes during continuous exercise. Intra- and inter-observer reproducibility were excellent. Inter-scan LV and RV ejection fraction were also highly reproducible.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据