4.1 Article

Improved Component Placement Accuracy with Robotic-Arm Assisted Total Knee Arthroplasty

期刊

JOURNAL OF KNEE SURGERY
卷 35, 期 3, 页码 337-344

出版社

GEORG THIEME VERLAG KG
DOI: 10.1055/s-0040-1715571

关键词

robotic-arm assisted; TKA; component position

向作者/读者索取更多资源

Robotic-arm assisted total knee arthroplasty (RATKA) demonstrates greater three-dimensional accuracy for component position compared to conventional total knee arthroplasty (TKA). Real-time intraoperative feedback and stereotactic-guided cutting, considering patient-specific bony anatomy, may contribute to these results. These findings support the use of RATKA for improved arthroplasty outcomes.
Component position of total knee arthroplasty (TKA) has been shown to influence prosthetic survivorships and clinical outcomes. Our objective was to compare the three-dimensional accuracy to plan of robotic-arm assisted TKA (RATKA) with conventional TKA for component position. We conducted a nonrandomized, prospective study comparing 143 RATKA with 86 conventional TKA operated at four U.S. centers between July 2016 and October 2018. Computed tomography (CT) scans obtained approximately 6 weeks postoperatively were analyzed using anatomical landmarks. Absolute deviation from surgical plans were defined as the absolute value of the difference between the CT measurements and surgeons' femoral and tibial component mechanical varus/valgus alignment, tibial component posterior slope, and femoral component internal/external rotation. Differences of absolute deviations were tested using stratified Wilcoxon's tests that controlled for study center. Patient-reported outcome measures collected through 1 postoperative year were modeled using multiple regression controlling for age, sex, body mass index, study center, and the preoperative score. RATKA demonstrated greater accuracy for tibial component alignment (median [25th, 75th percentiles] absolute deviation from plan of all centers combined for conventional vs. RA, 1.7 [0.9, 2.9] vs. 0.9 [0.4, 1.9] degrees,p < 0.001), femoral component rotation (1.5 [0.9, 2.5] vs. 1.3 [0.6, 2.5] degrees,p = 0.015), and tibial slope (2.9 [1.5, 5.0] vs. 1.1 [0.6, 2.0] degrees,p < 0.001). In multivariable analyses, RATKA showed significantly greater Veterans RAND 12-item health survey (VR-12) physical component scores (adjusted mean difference [95% confidence interval (CI)]: 2.4 [0.2, 4.5] points,p = 0.034) and qualitatively greater Knee Society (KS) composite functional scores (3.5 [-1.3, 8.2] points,p = 0.159), though not statistically significant. Compared with conventional instrumentation, RATKA demonstrated greater three-dimensional accuracy to plan for various component positioning parameters and clinical improvements in physical status and function with no major safety concerns during the first postoperative year. These results may be attributed to the preoperative CT scan planning, real-time intraoperative feedback, and stereotactic-guided cutting that takes into consideration patient-specific bony anatomy. These findings support the use of RATKA for enhanced arthroplasty outcomes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据