4.5 Article

High-Sensitivity Capsule-Shaped Sensor Based on 2D Photonic Crystals

期刊

SYMMETRY-BASEL
卷 12, 期 9, 页码 -

出版社

MDPI
DOI: 10.3390/sym12091480

关键词

detection limit; microcavity; photonic crystal; quality factor; sensitivity; sensor; waveguide

资金

  1. IFO Profession Development Funds, Metropolitan State University, USA

向作者/读者索取更多资源

This paper presents a new capsule-shaped sensor to detect the glucose concentration in the human body. The model under study was formulated by relying on the index change in the refractive index (RI) because of the change in the sample that infiltrated the cavity. The index of refraction change is accompanied by modifying the resonant wavelength. The recommended model has considered the simple shape and ease of manufacture, along with other characteristics such as sensitivity and a low detection limit. The results report a high sensitivity of S = 546.72 nm/RI unit (RIU), a high quality factor of Q = 2066.24, a low detection limit of DL = 1.44 x 10(-4) RIU, and a high value of transmission of 97%, which are considered to be sufficient and efficient in detecting measured material. This proposed model provides many opportunities and is promising for the manufacture of different types of sensing detection devices.