4.6 Article

Pronounced haemodynamic changes during and after robotic-assisted laparoscopic prostatectomy: a prospective observational study

期刊

BMJ OPEN
卷 10, 期 10, 页码 -

出版社

BMJ PUBLISHING GROUP
DOI: 10.1136/bmjopen-2020-038045

关键词

anaesthesia in urology; adult anaesthesia; heart failure; ischaemic heart disease; hypertension

向作者/读者索取更多资源

Objectives Robotic-assisted laparoscopic prostatectomy (RALP) is typically conducted in steep Trendelenburg position (STP). This study investigated the influence of permanent 45 degrees STP and capnoperitoneum on haemodynamic parameters during and after RALP. Design Prospective observational study. Setting Haemodynamic changes were recorded with transpulmonary thermodilution and pulse contour analysis in men undergoing RALP under standardised anaesthesia. Participants Informed consent was obtained from 51 patients scheduled for elective RALP in a University Medical Centre in Germany. Interventions Heart rate, mean arterial pressure, central venous pressure (CVP), Cardiac Index (CI), systemic vascular resistance (SVR), Global End-Diastolic Volume Index (GEDI), global ejection fraction (GEF), Cardiac Power Index (CPI) and stroke volume variation (SVV) were recorded at six time points: 20 min after induction of anaesthesia (T1), after insufflation of capnoperitoneum in supine position (T2), after 30 min in STP (T3), when controlling Santorini's plexus in STP (T4), before awakening in supine position (T5) and after 45 min in the recovery room (T6). Adverse cardiac events were registered intraoperatively and postoperatively. Results All haemodynamic parameters were significantly changed by capnoperitoneum and STP during RALP and partly normalised at T6. CI, GEF and CPI were highest at T6 (CI: 3.9 vs 2.2 L/min/m(2); GEF: 26 vs 22%; CPI: 0.80 vs 0.39 W/m(2); p<0.001). CVP was highest at T4 (31 vs 7 mm Hg, p<0.001) and GEDI at T6 (819 vs 724 mL/m(2), p=0.005). Mean SVR initially increased (T2) but had decreased by 24% at T6 (p<0.001). SVV was highest at T5 (12 vs 9%, p<0.001). Two of the patients developed cardiac arrhythmia during RALP and one patient suffered postoperative cardiac ischaemia. Conclusions RALP led to pronounced perioperative haemodynamic changes. The combination of increased cardiac contractility and heart rate reflects a hyperdynamic situation during and after RALP. Anaesthesiologists should be aware of unnoticed pre-existing heart failure to worsen during STP in patients undergoing RALP.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据