4.2 Article

Non-phthalate plasticizer DENT preserves adequate blood component quality during storage in PVC blood bags

期刊

VOX SANGUINIS
卷 116, 期 1, 页码 60-70

出版社

WILEY
DOI: 10.1111/vox.12982

关键词

DEHT; DEHP; phthalates; plasticizers; blood components; red blood cells

资金

  1. Macopharma

向作者/读者索取更多资源

This study compared blood bags made with DEHT and DEHP plasticizers, finding that although there was slightly higher hemolysis in DEHT, all results remained below the European limit. DEHT was shown to provide adequate blood component quality and is proposed as a strong candidate for replacing DEHP in blood bags.
Background and objectives Commercial blood bags are predominantly made of polyvinyl chloride (PVC) plasticized with di(2-ethylhexyl) phthalate (DEHP). DEHP is favourable for storage of red blood cells (RBC). Historically, removal of DEHP from blood bags has been linked to unacceptable haemolysis levels. Oncoming regulatory restrictions for DEHP due to toxicity concerns increase the urgency to replace DEHP without compromising RBC quality. Di(2-ethylhexyl) terephthalate (DEHT) is one suggested substitute. The aim of this study was to compare PVC-DEHT to PVC-DEHP blood bags using additive solutions saline- adenine-glucose-mannitol (SAGM) and phosphate-adenine-glucose-guanosine- saline-mannitol (PAGGSM), to determine whether DEHT can maintain acceptable component quality. Materials and methods RBC concentrates (N = 64), platelet concentrates (N = 16) and fresh frozen plasma (N = 32) were produced from whole blood collected into either DEHT or DEHP plasticized systems. Using a pool-and-split study design, pairs of identical RBC content were created within each plasticizer arm and assigned either SAGM or PAGGSM. Storage effects were assessed weekly for 49 days (RBC), 7 days (platelets) and before/after freezing (plasma). Results Though haemolysis was slightly higher in DEHT, all study arms remained below half of the European limit 0-8 %. K+ was lower in DEHT than in DEHP independent of additive solution. The metabolic parameters were not influenced by choice of plasticizer. Platelet activation/metabolism and plasma content were similarly preserved. Conclusion Our study demonstrates that the plasticizer DEHT provides adequate blood component quality. We propose DEHT as a strong future candidate for replacement of DEHP in blood bags.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据