4.6 Article

Value of cervical electrical impedance spectroscopy to predict spontaneous preterm delivery in asymptomatic women: the ECCLIPPx prospective cohort study

期刊

ULTRASOUND IN OBSTETRICS & GYNECOLOGY
卷 58, 期 2, 页码 293-302

出版社

WILEY
DOI: 10.1002/uog.22180

关键词

cervical length; electrical impedance spectroscopy; fetal fibronectin; pregnancy; preterm birth; screening

资金

  1. Medical Research Council of the UK [MR/J014788/1]
  2. MRC [MR/J014788/1] Funding Source: UKRI

向作者/读者索取更多资源

The study examined the predictive performance of cervical probe device based on electrical impedance spectroscopy (EIS) for preterm birth (PTB). Cervical EIS showed promising results in predicting spontaneous PTB, especially when combined with a history of previous PTB. Larger confirmatory studies are needed to assess the clinical utility of mid-trimester cervical EIS assessment.
Objectives Preterm birth (PTB) accounts for two-thirds of deaths of structurally normal babies and is associated with substantial lifetime healthcare costs. Prevention of PTB remains limited by the modest accuracy of prediction methods, namely transvaginal ultrasound (TVS) cervical length (CL) measurement and quantitative cervicovaginal fetal fibronectin (FFN) estimation. We report the first substantive study detailing the predictive performance of a cervical probe device based on electrical impedance spectroscopy (EIS) for PTB - the EleCtriCaL Impedance Prediction of Preterm birth by spectroscopy of the cervix (ECCLIPPx) study. We aimed to compare the accuracy of cervical EIS-based prediction of spontaneous PTB with that of prediction using TVS-CL and FFN in asymptomatic women in the mid-trimester. Methods We studied asymptomatic women with a singleton pregnancy at 20-22 weeks' and 26-28 weeks' gestation. EIS was performed using a Sheffield Mark 5.0 device that makes measurements in the frequency range 76 Hz to 625 kHz using a small probe housing tetrapolar electrodes. TVS-CL and FFN were also measured. The associations of cervical EIS, TVS-CL and FFN with spontaneous delivery before 37weeks and before 32 weeks were determined by multivariate linear and non-linear logistic regression analysis. Areas under the receiver-operating-characteristics curves (AUC) plots of sensitivity against specificity were used to compare the predictive performance of all parameters, both in isolation and in combination. Results Of the 365 asymptomatic women studied at 20-22weeks who were not receiving treatment, 29 had spontaneous PTB, 14 had indicated PTB and 322 had term birth. At the higher frequencies assessed, cervical EIS predicted spontaneous PTB before 37weeks with an AUC of 0.76 (95% CI, 0.71-0.81), compared with AUCs of 0.72 (95% CI, 0.66-0.76) for TVS-CL and 0.62 (95% CI, 0.56-0.72) for FFN. Combining all three assessments improved the prediction of spontaneous PTB before 37 weeks (AUC, 0.79 (95% CI, 0.74-0.83)) compared with TVS-CL and FFN alone. Incorporating a history of spontaneous PTB (defined as previous mid-trimester miscarriage or spontaneous PTB (14 to < 37 weeks)) into the cervical EIS prediction model improved the accuracy of prediction of spontaneous PTB before 37weeks (AUC, 0.83 (95% CI, 0.78-0.87)) and before 32 weeks (AUC, 0.86 (95% CI, 0.82-0.90)). Conclusions Mid-trimester cervical EIS assessment predicts spontaneous PTB. Larger confirmatory studies investigating its potential clinical utility and to inform effective preventive interventions are required. (C) 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据