4.6 Article

Evaluation of MCC seismic response according to the frequency contents through the shake table test

期刊

NUCLEAR ENGINEERING AND TECHNOLOGY
卷 53, 期 4, 页码 1345-1356

出版社

KOREAN NUCLEAR SOC
DOI: 10.1016/j.net.2020.10.002

关键词

Shake table test; Natural frequency; Seismic fragility test; Uniform hazard spectra; Design spectrum

资金

  1. Korea Institute of Energy Technology Evaluation and Planning (KETEP)
  2. Ministry of Trade, Industry, and Energy (MOTIE) of the Republic of Korea [20201510100010]

向作者/读者索取更多资源

The study conducted shaking table tests on electrical facilities in nuclear power plants under different earthquake conditions, focusing on the response characteristics and safety of high-frequency component earthquakes. The safety of electrical facilities was confirmed through limit-state seismic tests.
Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limitstate seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC). ? 2020 Korean Nuclear Society, Published by Elsevier Korea LLC. All rights reserved. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据