4.4 Article

Long-term complications and implant survival rates after cranioplastic surgery: a single-center study of 392 patients

期刊

NEUROSURGICAL REVIEW
卷 44, 期 3, 页码 1755-1763

出版社

SPRINGER
DOI: 10.1007/s10143-020-01374-4

关键词

Autologous cranioplasty; CAD; CAM implant; Cranioplasty; Decompressive craniectomy; Multidrug-resistant bacteria; PMMA

资金

  1. Projekt DEAL

向作者/读者索取更多资源

This study retrospectively analyzed 392 patients who underwent cranioplasty surgery between 2004 and 2014, identifying young age, presence of multidrug-resistant bacteria, and cerebrospinal fluid shunt as risk factors for postoperative complications. The use of titanium miniplates for cranioplasty fixation was associated with reduced complication rates and longer implant survival time.
Cranioplasty (CP) is a standard procedure in neurosurgical practice for patients after (decompressive) craniectomy. However, CP surgery is not standardized, is carried out in different ways, and is associated with considerable complication rates. Here, we report our experiences with the use of different CP materials and analyze long-term complications and implant survival rates. We retrospectively studied patients who underwent CP surgery at our institution between 2004 and 2014. Binary logistic regression analysis was performed in order to identify risk factors for the development of complications. Kaplan-Meier analysis was used to estimate implant survival rates. A total of 392 patients (182 females, 210 males) with a mean age of 48 years were included. These patients underwent a total of 508 CP surgeries. The overall complication rate of primary CP was 33.2%, due to bone resorption/loosening (14.6%) and graft infection (7.9%) with a mean implant survival of 120 +/- 5 months. Binary logistic regression analysis showed that young age (< 30 years) (p = 0.026, OR 3.150), the presence of multidrug-resistant bacteria (p = 0.045, OR 2.273), and cerebrospinal fluid (CSF) shunt (p = 0.001, OR 3.137) were risk factors for postoperative complications. The use of titanium miniplates for CP fixation was associated with reduced complication rates and bone flap osteolysis as well as longer implant survival rates. The present study highlights the risk profile of CP surgery. Young age (< 30 years) and shunt-dependent hydrocephalus are associated with postoperative complications especially due to bone flap autolysis. Furthermore, a rigid CP fixation seems to play a crucial role in reducing complication rates.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据