4.5 Article

Quantification of Aerosol Concentrations During Endonasal Instrumentation in the Clinic Setting

期刊

LARYNGOSCOPE
卷 131, 期 5, 页码 E1415-E1421

出版社

WILEY
DOI: 10.1002/lary.29122

关键词

COVID-19; nasal endoscopy; aerosol-generating procedures; optical particle sizer; droplet quantification

资金

  1. NIH [KL2TR002490]
  2. Howard Holderness Distinguished Medical Scholars program
  3. Pillsbury Medical Student Research Fellowship Grants

向作者/读者索取更多资源

Recent study examined aerosol generation during nasal endoscopy and found no significant increase in aerosol particles during diagnostic procedures in patients without need for debridement. However, in patients needing debridement, cold and suction instrumentation were associated with increased aerosol generation, with a trend observed during endoscope use prior to tissue manipulation.
Objective Recent anecdotal reports and cadaveric simulations have described aerosol generation during endonasal instrumentation, highlighting a possible risk for transmission of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) during endoscopic endonasal instrumentation. This study aims to provide a greater understanding of particle generation and exposure risk during endoscopic endonasal instrumentation. Study Design Prospective quantification of aerosol generation during office-based nasal endoscopy procedures. Methods Using an optical particle sizer, airborne particles concentrations 0.3 to 10 microns in diameter, were measured during 30 nasal endoscopies in the clinic setting. Measurements were taken at time points throughout diagnostic and debridement endoscopies and compared to preprocedure and empty room particle concentrations. Results No significant change in airborne particle concentrations was measured during diagnostic nasal endoscopies in patients without the need for debridement. However, significant increases in mean particle concentration compared to preprocedure levels were measured during cold instrumentation at 2,462 particles/foot(3)(95% CI 837 to 4,088;P= .005) and during suction use at 2,973 particle/foot(3)(95% CI 1,419 to 4,529;P= .001). In total, 99.2% of all measured particles were <= 1 mu m in diameter. Conclusion When measured with an optical particle sizer, diagnostic nasal endoscopy with a rigid endoscope is not associated with increased particle aerosolization in patient for whom sinonasal debridement is not needed. In patients needing sinonasal debridement, endonasal cold and suction instrumentation were associated with increased particle aerosolization, with a trend observed during endoscope use prior to tissue manipulation. Endonasal debridement may potentially pose a higher risk for aerosolization and SARS-CoV-2 transmission. Appropriate personal protective equipment use and patient screening are recommended for all office-based endonasal procedures. Level of Evidence 3Laryngoscope, 2020

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据