4.7 Article

Effects of a rotating tube bundle on the hydrothermal performance for forced convection in a vented cavity with Ag-MgO/water hybrid and CNT-water nanofluids

期刊

JOURNAL OF THERMAL ANALYSIS AND CALORIMETRY
卷 147, 期 1, 页码 939-956

出版社

SPRINGER
DOI: 10.1007/s10973-020-10251-7

关键词

Rotating tube bundle; Finite volume method; CNT nanofluid; Hybrid nanofluid; Vented cavity

向作者/读者索取更多资源

This study investigated the effects of a rotating tube bundle on the hydrothermal performance of forced convection in a vented cavity. The results showed that the rotational effects of the tube bundle had an impact on the heat transfer. The use of CNT particles led to higher heat transfer coefficients and lower pressure coefficients compared to the hybrid nanofluid.
In this study, effects of rotating tube bundle on the hydrothermal performance for the forced convection in a vented cavity are numerically studied with a mixture of Ag and MgO nanoparticles suspended in water, forming a hybrid nanofluid and CNT-water nanofluid. The finite volume method is used for the numerical simulations. The simulation study is performed for various values of Reynolds number (between 100 and 1000), rotational Reynolds number (between - 100 and 100), size (between 0.01H and 0.12H), vertical (between 0.3H and 0.65H) and horizontal locations (between 0.3H and 0.65H) of the cylinder in the tube bundle and nanoparticle volume fraction (between 0 and 0.02). An experimental correlation was used for the description of the Ag-MgO/water hybrid nanofluid. Results indicated that the rotational effects of the tube bundle contribute to the hydrothermal performance. The average Nusselt number enhancements are 8.95% and 40% when CNT-water is used for solid volume fraction of 0.02 at the highest speed, while these values are 31.5% and 37.7% for hybrid nanofluid. The pressure coefficients are higher for negative value of Re-omega and hybrid nanofluid. The size of the tube bundle is effective at the highest size, while the increment amount is 16.8% both for CNT-water and for hybrid nanofluids. The center location of the tube bundle resulted in heat transfer enhancement which is in the range of 11% and 18%. As the solid volume fraction of nanoparticles becomes higher, discrepancies between the average Nu values of CNT-water nanofluid and Ag-MgO/water hybrid nanofluid become higher which is also observed for the pressure coefficient. It is advantageous to use CNT particles since higher heat transfer coefficients with lower values of pressure coefficient are obtained.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据