4.3 Article

Early postoperative complications after Latarjet procedure: a single-institution experience over 10 years

期刊

JOURNAL OF SHOULDER AND ELBOW SURGERY
卷 30, 期 6, 页码 E300-E308

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.jse.2020.09.002

关键词

Shoulder instability; Latarjet procedure; complications; graft failure; failed Bankart repair; nerve injury; screw divergence angle

向作者/读者索取更多资源

The Latarjet procedure is effective for treating anterior glenohumeral joint instability, but complications are common, with graft- and nerve-related complications being significant. Fixation with only 1 screw and an increased screw divergence angle are significant predictors of graft failure.
Background: The Latarjet procedure is an effective procedure for the treatment of anterior glenohumeral joint instability; however, the complications are concerning. The purpose of this study was to review a single institution's experience with the Latarjet procedure for recurrent anterior glenohumeral instability specifically focusing on early complications. Methods: This was a retrospective review of all Latarjet procedures performed at a single institution from August 2008 to July 2018. The 90-day complication rate and associated risk factors for all complications and graft failure were recorded. Postoperative radiographs were reviewed for coracoid graft position and screw divergence. Results: During the study period, 190 Latarjet procedures were performed with 90-day follow-up. The average age was 28.7 +/- 11.3 years, male patients comprised 84.2% of the population, and 62.6% of patients had undergone a prior stabilization procedure. We observed 15 complications, for a 90-day complication rate of 9.0%; of the patients, 8 (4.2%) underwent reoperations. Graft or hardware failure occurred in 9 patients (4.7%) with loosened or broken screws, and 6 required reoperations (revision Latarjet procedure in 4, distal tibia allograft in 1, and iliac crest autograft in 1). Fixation with only 1 screw (P < .001) and an increased screw divergence angle (37 degrees +/- 8 degrees vs. 24 degrees 11 degrees, P = .0257) were statistically associated with graft failure, whereas the use of cannulated screws (P = .487) was not. There were 6 nerve injuries (3.2%), including 2 combined axillary and suprascapular nerve injuries, 1 musculocutaneous nerve injury, 1 brachial plexopathy, 1 peripheral sensory nerve deficit (likely axillary), and 1 sensory plexopathy. Suprascapular nerve injury at the spinoglenoid notch was associated with a longer superior screw (41.0 +/- 1.4 mm vs. 33.5 +/- 3.5 mm, P = .035) and increased screw divergence angle (40 degrees +/- 6 degrees vs. 24 degrees +/- 11 0 , P = .0197). The coracoid graft was correctly positioned in the axial plane in 71% of cases and in the coronal plane in 73% of cases. Conclusion: The Latarjet procedure is a procedure that can reliably restore shoulder stability; however, graft- and nerve-related complications are relatively common. Two-thirds of the graft failures required reoperations, and half of the nerve injuries in this study led to residual symptoms. Fixation with only 1 screw and an increased screw divergence angle were significant predictors of graft failure. Suprascapular nerve injury at the spinoglenoid notch was associated with an increased screw divergence angle and longer superior screw. (C) 2020 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据