4.4 Article

A new diagnostic indication device of a biomarkergrowth differentiation factor 15for mitochondrial diseases: From laboratory to automated inspection

期刊

JOURNAL OF INHERITED METABOLIC DISEASE
卷 44, 期 2, 页码 358-366

出版社

WILEY
DOI: 10.1002/jimd.12317

关键词

biomarker; diagnostic indication device; GDF15; latex; LTIA; mitochondrial disease

资金

  1. Japan Agency for Medical Research and Development [JP17ek0109088, JP19ek0109336]
  2. Japan Society for the Promotion of Science [JP25461571]

向作者/读者索取更多资源

GDF15 is a useful biomarker for diagnosing and evaluating MDs, and the newly developed LTIA device shows potential in serum concentration measurement.
Mitochondrial diseases (MDs) are occasionally difficult to diagnose. Growth differentiation factor 15 (GDF15) has been reported as a biomarker useful for not only diagnosing MDs, but also evaluating disease severity and therapeutic efficacy. To enable the measurement of serum GDF15 concentrations at medical institutions, we developed a new latex-enhanced turbidimetric immunoassay (LTIA) as an automated diagnostic indication test for MDs. We also examined the equivalency of specificity and sensitivity in measuring serum GDF15 concentrations between a commercially available enzyme-linked immunosorbent assay (ELISA) kit and a novel LTIA device in patients with MDs, disease controls, and healthy controls. A clinical performance study used a newly developed LTIA device and an existing ELISA kit to measure the concentrations of GDF15 in 35 MD patients, 111 disease controls, and 86 healthy controls. The median (first quartile-third quartile) of serum GDF15 concentrations measured with the LTIA device was significantly higher (P < .001) in MD patients (1389.0 U/mL [869.5-1776.0 U/mL]) than in healthy controls (380.5 U/mL [330.2-471.8 U/mL]); the interquartile ranges did not overlap between MD patients and healthy controls. The areas under the curve in disease and healthy controls were 0.812 (95% confidence interval [CI]: 0.734-0.886) and 0.951 (95% CI: 0.910-0.992), respectively. The automated, high-throughput technology-based LTIA device has definite advantages over the ELISA kit in shorter processing time and lower estimated cost per sample measurement. The LTIA device of GDF15 may be a sufficiently reliable, frontline, diagnostic indicator of individuals with suspected MDs in the general population.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据