The study evaluated different methods for detecting carbapenemases, with mCIM-A showing better performance for OXA-48-like and NDM enzymes. The mCIM-A method is a simple and useful tool for identifying CPEs in clinical microbiology laboratories.
Introduction: The emergence and spread of carbapenemase-producing Enterobacterales (CPE) is a worldwide public health threat. Rapid and accurate detection of CPE is essential to prevent their dissemination within health care settings. The aim of this study was to evaluate the performance of CIM, mCIM and mCIM with ammonium bicarbonate (mCIM-A) methods by using different interpretation criteria for detection of carbapenemases. Methods: One hundred and fifty-three Klebsiella pneumoniae isolates previously characterized by molecular tests, including 133 carbapenemase producers and 20 non-carbapenemase producers, were collected in this study. CIM and mCIM tests were performed as described previously. mCIM-A by adding 50 mM ammonium bicarbonate to the bacterial suspension prepared in tryptic soy broth. The inhibition zone diameter of around meropenem disc was measured and interpreted as positive according to i) Pierce and colleagues (<19 mm), ii) EUCAST meropenem susceptibility breakpoint (<22). Results: CIM, although seems to be good for carbapenemases other than OXA-48-like and NDM, is not satisfactory (42.3% and 83.4%, respectively) for those enzymes with any of the interpretation criteria. OXA-48-like and NDM were detected with a better performance (88.7% and 92.8, respectively) with mCIM when results were interpreted according to <22 mm zone diameter for OXA-48-like and NDM. The best results were obtained with mCIM-A using <22 mm criteria without any difference in the results of other enzymes and negative strains. Conclusions: mCIM- A method interpreted with <22 mm meropenem zone diameter seems to be preferable compared to CIM and mCIM. mCIM-A is simple and useful tool for identification of CPEs in clinical microbiology laboratories. (C) 2020 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据