4.6 Article

Determination of germanium in plant and soil samples using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) with solid sampling

期刊

JOURNAL OF GEOCHEMICAL EXPLORATION
卷 220, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.gexplo.2020.106674

关键词

Solid sampling; Germanium; High-resolution continuum-source atomic absorption spectroscopy; Environmental samples

资金

  1. Federal Ministry of Education and Research, Germany [033R091]

向作者/读者索取更多资源

A modified AAS method using HR CS GFAAS was developed for the determination of Ge in solid samples, without the need for time-consuming sample preparation steps. The results obtained showed a good agreement with those obtained using ICP-MS. The detection limit for Ge was down to 500 μg kg(-1), making the method suitable for routine analysis in geochemical laboratories.
Germanium (Ge) is commonly an unreported trace element in environmental samples due to the lack of reliable analytical methods. Besides atomic mass spectrometric methods (ICP-MS) and atomic emission spectroscopy (OES), graphite furnace atomic absorption spectrometry (GFAAS) offers the sensitivity that is needed in biological and environmental analysis. However, until recently AAS-techniques for the quantification of Ge were solely described for liquid samples and require time consuming sample preparation steps involving total dissolution of the sample matrix. In the present study we modified an existing method for the determination of Ge in liquid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR CS GFAAS) towards its applicability to solid samples. Similar to liquid HR CS AAS, the addition of Pd/Mg(NO3)(2) as modifier was necessary to avoid analyte losses. To achieve a homogeneous wetting of the solid sample Triton X-100, a non-ionic surfactant, was added together with the modifier. A biomass weight of 0.1-0.2 mg was appropriate for the solid sampling set-up, to which 20 mu L of modifier, including 0.1% surfactant, was added. The furnace temperatures were adjusted to 90-140 degrees C for the drying process, to 1500 ?C for pyrolysis and to 2550 degrees C for the atomisation step. Various calibration options were also considered realising routine analysis. Considering Ge concentrations in various environmental samples we observed no significant differences between results obtained from HR CS AAS and ICP-MS, respectively. The analytical technique demonstrated a detection limit for Ge down to 500 mu g kg(-1) Ge by a characteristic mass of 50 pg for selected biomass samples. The novel method can be applied in geochemical laboratories equipped with HR CS GFAAS devices to determine Ge in range of 0.7-360 mg kg(-1) Ge in solid environmental samples without any sample preparation steps except of grinding.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据