4.4 Article

Evaluation of spectral induced polarization field measurements in time and frequency domain

期刊

JOURNAL OF APPLIED GEOPHYSICS
卷 180, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.jappgeo.2020.104141

关键词

Induced polarization (IP); Time domain IP (TDIP); Frequency domain IP (FDIP); Spectral bandwidth; Comparison; Graptolite shale

资金

  1. European Union's Horizon 2020 Research and Innovation Program under the Marie Sklodowska-Curie Grant [752671]
  2. Swedish AForsk Foundation [18-453]
  3. Marie Curie Actions (MSCA) [752671] Funding Source: Marie Curie Actions (MSCA)

向作者/读者索取更多资源

Spectral induced polarization (SIP) measurements have been demonstrated to correlate with important parameters in hydrogeological and environmental investigations. Although SIP measurements were often collected in the frequency domain (FDIP), recent developments have demonstrated the capabilities to solve for the frequency-dependence of the complex conductivity through measurements collected in the time domain (TDIP). Therefore, the aim of our field investigations is a comparison of the measured frequency-dependence at a broad frequency range resolved through FDIP and TDIP. In contrast to previous studies, we conducted measurements with different instruments and measuring technologies for both FDIP and TDIP. This allows for investigating the robustness of different measurements and assessing various sources of errors, for the assessment of the advantages and drawbacks from different measuring techniques. Our results demonstrate that data collected through different instruments are consistent. Apparent resistivity measurements as well as the inversion results revealed quantitatively the same values for all instruments. The measurements of the IP effect are also comparable, particularly FDIP readings in the low frequencies (< 10 Hz) revealed to be quantitatively the same for different instruments. TDIP measurements are consistent for data collected with both devices. As expected, the spatial distribution of the values is also consistent for low frequency data (in FDIP) and late times measurements in TDIP (> 0.1 s). However, data quality for higher frequencies in FDIP (i.e., early times in TDIP) show larger variations, which reflects the differences between the instruments to deal with the electromagnetic contamination of the IP data. Concluded in general, the different instruments and measuring techniques can provide consistent responses for varying signal-to-noise ratio and measuring configurations. (C) 2020 The Authors. Published by Elsevier B.V.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据