Comparison of O-RADS, GI-RADS, and IOTA simple rules regarding malignancy rate, validity, and reliability for diagnosis of adnexal masses

期刊

EUROPEAN RADIOLOGY
卷 31, 期 2, 页码 674-684

出版社

SPRINGER
DOI: 10.1007/s00330-020-07143-7

关键词

Adnexal diseases; Ultrasonography; Data systems; Sensitivity and specificity; Reproducibility of results

向作者/读者索取更多资源

The study compared the effectiveness of O-RADS with two other well-established US classification systems for diagnosing AM. O-RADS showed higher sensitivity for malignancy compared to GI-RADS and IOTA, with similar specificity and reliability. Inter-reviewer agreement was slightly higher for O-RADS compared to GI-RADS and IOTA.
Objective The American College of Radiology (ACR) recently published the ovarian-adnexal reporting and data system (O-RADS) to provide guidelines to physicians who interpret ultrasound (US) examinations of adnexal masses (AM). This study aimed to compare the O-RADS with two other well-established US classification systems for diagnosis of AM. Methods This retrospective multicenter study between May 2016 and December 2019 assessed consecutive women with AM detected by the US. Five experienced consultant radiologists independently categorized each AM according to O-RADS, gynecologic imaging reporting and data system (GI-RADS), and international ovarian tumor analysis (IOTA) simple rules. Pathology and adequate follow-up were used as reference standards for calculating the validity of three US classification systems for diagnosis of AM. Kappa statistics were used to assess the inter-reviewer agreement (IRA). Results A total of 609 women (mean age, 48 +/- 13.7 years; range, 18-72 years) with 647 AM were included. Of the 647 AM, 178 were malignant and 469 were benign. Malignancy rates were comparable to recommended rates by previous literature in O-RADS and IOTA, but higher in GI-RADS. O-RADS had significantly higher sensitivity for malignancy than GI-RAD and IOTA (p= 0.003 and 0.0007, respectively), but non-significant slightly lower specificity (p> 0.05). O-RADS, GI-RADS, and IOTA showed similar overall IRA (kappa= 0.77, 0.69, and 0.63, respectively) with a tendency toward higher IRA with O-RADS than with GI-RADS and IOTA. Conclusions O-RADS compares favorably with GI-RADS and IOTA. O-RADS had higher sensitivity than GI-RADS and IOTA simple rules with relatively similar specificity and reliability.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据