Modeling and numerical investigation for hygrothermal behavior of porous building envelope subjected to the wind driven rain

期刊

ENERGY AND BUILDINGS
卷 231, 期 -, 页码 -

出版社

ELSEVIER SCIENCE SA
DOI: 10.1016/j.enbuild.2020.110572

关键词

Porous media; Coupled heat and moisture transfer; Wind driven rain; Hygrothermal; Cooling load; Heating load

资金

  1. China National Key R&D Program during the 13th Five-year Plan Period [2017YFC0702201]
  2. Natural Science Foundation of China [51078127]

向作者/读者索取更多资源

The study presented a numerical model and analysis method for the hygrothermal behavior of building walls exposed to wind driven rain. The results show that wind driven rain has a significant influence on the hygrothermal performance of building walls, emphasizing the importance of incorporating it into hygrothermal transfer models for optimal design and accurate energy simulation in rainy areas.
Wind driven rain (WDR) may have serious effect on the heat transfer through exterior wall, optimal design of envelope, and building energy consumption simulation. Accurate evaluation of the impact of WDR on the hygrothermal performance of building envelope is important for energy-saving design of buildings. This work presented the numerical model and analysis method for the hygrothermal behavior of building wall exposed to the WDR. A capillary pressure based coupled heat and moisture (CHM) transfer model applicable to the high humidity condition was established and validated. The IS015927-3 method of WDR was improved based on the previous experimental results. WDR on four orientation walls were investigated use the improved ISO method and weather station data between November 2017 and October 2018 in the representative city of Changsha. Dynamic simulation of hygrothermal performance for external wall is conducted under three calculation conditions: the transient heat conduction (TH), CHM (no rain) and CHM (WDR) models. The results show that total cooling load transmitted through the east, south, west and north orientation walls calculated with CHM (no rain) model is predicted to increase 8.5%, 8.6%, 5.3% and 10.3% compared to the TH model. But total cooling load transmitted through the four orientation walls calculated with CHM (WDR) model separately increases -2.5%, 1.8%, -7.9% and -46.1% in contrast with TH model. Total heating load transmitted through the four orientation walls calculated with CHM (WDR) model is predicted to separately increase 3.2%, 3.2%, 63.3% and 71.5% compared to the TH model. The results indicate that WDR has significant influence on the hygrothermal performance of building wall. It is essential to incorporate the WDR into the hygrothermal transfer model for the validity of optimal design and the accuracy of building energy simulation in rainy areas. (C) 2020 Elsevier B.V. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据