4.4 Article

A comparison of test-retest reliability and random measurement error of the Barthel Index and modified Barthel Index in patients with chronic stroke

期刊

DISABILITY AND REHABILITATION
卷 44, 期 10, 页码 2099-2103

出版社

TAYLOR & FRANCIS LTD
DOI: 10.1080/09638288.2020.1814429

关键词

Barthel Index; modified Barthel Index; activities of daily living; stroke; test-retest reliability; random measurement error

资金

  1. Chung Shan Medical University
  2. Chi Mei Medical Center [CSMU-CMMC-106-05, CMCSMU10606]

向作者/读者索取更多资源

This study aimed to compare the test-retest reliability and random measurement errors of the Barthel Index (BI) and modified Barthel Index (MBI) in patients with chronic stroke. The results showed that the MBI had better test-retest reliability and relatively lower random measurement error, suggesting that it may be a better measure for activities of daily living (ADL) in these patients.
Objective To compare the test-retest reliability and random measurement errors of the Barthel Index (BI) and modified Barthel Index (MBI) in patients with chronic stroke. Method The intraclass correlation coefficient (ICC) and the minimal detectable change (MDC) were applied respectively to examine the test-retest reliability (about 2 weeks apart) and the random measurement errors. The MDC% was used to adjust the cut-off score for determining whether a real change had been achieved, if heteroscedasticity existed. Results A total of 60 patients participated. The BI and MBI both had high ICCs (0.94 and 0.94, respectively) with small MDCs (16.2 and 15.4, respectively) and MDC%s (21.2% and 19.0%, respectively), indicating that both measures have comparable reliability in repeated assessments. However, moderate associations (r= -0.47 for the BI and -0.59 for the MBI) were found between the means of tests and retests and the absolute values of change scores, indicating heteroscedasticity. These findings suggest that a fixed MDC value is not appropriate for determining the real change in both measures because the amount of random measurement error varies with the patients' ADL function. Conclusion The MBI, which showed excellent test-retest reliability and relatively lower random measurement error than the BI, appears to be a better ADL measure. The MDC% adjusted value is recommended to determine whether the change scores are beyond random measurement error.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据