4.3 Article

A Comparative Evaluation of Diffractive Trifocal and New Refractive/Extended Depth of Focus Intraocular Lenses for Refractive Lens Exchange

期刊

CURRENT EYE RESEARCH
卷 46, 期 6, 页码 811-817

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/02713683.2020.1833347

关键词

extended depth of focus; trifocal; quality of life; refractive lens exchange; presbyopia

向作者/读者索取更多资源

The study compared the visual performance and quality of life associated with two types of intraocular lenses, EDOF and trifocal IOLs, in refractive lens exchange patients. Results showed satisfactory refractive outcomes and visual acuities for both lens types, with EDOF design in the Lucidis IOL achieving lower rates of glare in the early period after surgery.
Purpose To evaluate and compare the visual performance and quality of life (QOL) associated with refractive/extended depth of focus (EDOF) intraocular lenses (IOLs) and diffractive trifocal IOLs in refractive lens exchange patients. Materials and methods This was a comparative interventional study of patients undergoing implantation of Lucidis (Swiss Advanced Vision, SAV-IOL SA, Neuchatel, Switzerland) or AT LISA tri 839MP (Carl Zeiss Meditec AG, Germany) IOLs. Near, intermediate, and distance best corrected and uncorrected visual acuities were collected at 1 and 3 months postoperatively. The vision-related QOL was evaluated 1 and 3 months after surgery, using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire). Results A total of 74 patients underwent refractive lens exchange and IOL implantation, with 38 patients in the EDOF group and 36 in the trifocal group. Among all visual acuities, uncorrected near visual acuity was statistically significantly better with the Lucidis IOL at the first month (p= .02) and diminished at the third-month visit (p= .16). When we compared the VF-14 QOL questionnaire scores, reading small print, reading a newspaper or book, and driving at night were statistically significantly better in the Lucidis group at the first month (p= .00, for each). That difference persisted only in driving at night at the third-month visit (p= .04). Reading small print, driving at night, and doing fine handwork were the most difficult tasks in the AT LISA group at the first month, and only driving at night remained so at the third-month visit. Conclusions The refractive results and visual outcomes at all distances of EDOF and trifocal IOLs were highly satisfactory. However, the EDOF design in the Lucidis IOL achieves lower rates of glare in the early period after refractive lens exchange.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据