4.7 Article

Use of artificial intelligence for tailored routine urine analyses

期刊

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.cmi.2020.09.056

关键词

Algorithms; CHROMIDCPSE; PhenoMATRIX; Urine; WASPLab artificial intelligence

资金

  1. bioMerieux
  2. Copan

向作者/读者索取更多资源

The study aimed to validate a workflow designed using artificial intelligence software PhenoMATRIX (PHM), with results showing over 90% agreement with LT results, potentially saving laboratory technologists' time.
Objectives: Urine is the most common material tested in clinical microbiology laboratories. Automated analysis is already performed, permitting quicker results and decreasing the laboratory technologist's (LT) workload. These automatic systems have introduced digital imaging concepts. PhenoMATRIX (PHM) is an artificial intelligence software that merges picture algorithms and user rules to provide presumptive results. This study aimed at designing a tailored workflow using PHM, performing its validation and checking its performance in routine practice. Methods: Two data collections including 96 and 135 urine samples from nephrostomy/ureterostomy and artificial bladder (US), 948 and 1257 urine samples from catheter (UC) and 3251 and 2027 midstream urine (MSU) were used to compare LT results with those obtained using two versions of PHM. Another 19 US, 102 UC and 508 MSU were used to monitor performance level 3 months after routine implementation. Results: Before and after revisions, agreement between the first version of PHM and LT results were 83% (95% confidence interval [CI], 74.3-90.2) and 83% (95% CI, 75.3-90.9) (US), 66.7% (95% CI, 63.5-69.5) and 71.7% (95% CI, 68.8-74.4) (UC) and 65.4% (95% CI, 63.8-67.1) and 76% (95% CI, 74.1-77.1) (MSU). The second version improved results, demonstrating 96.2% (95% CI, 91.6-98.8) and 97% (95% CI, 92.6-99.2) (US), 87.5% (95% CI, 85.5-89.2) and 88.9% (95% CI, 87.0-90.5) (UC) and 91% (95% CI, 89.7-92.1) and 92% (95% CI, 91.1-93.4) (MSU) of agreement with LT results before and after revisions. The reliability of PHM results was confirmed by a routine study demonstrating 92% (95% CI, 90.0-94.2) overall agreement. Conclusions: PHM showed high performance, with >90% of results in agreement with LT. PHM could help standardize and secure results, prioritize positive plates during analytical workflow and likely save LT time. (C) 2020 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据