4.7 Article

Higher Adenoma Detection Rates at Screening Associated With Lower Long-Term Colorectal Cancer Incidence and Mortality

期刊

CLINICAL GASTROENTEROLOGY AND HEPATOLOGY
卷 20, 期 2, 页码 E148-E167

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.cgh.2020.09.020

关键词

Adenoma Detection Rate; Flexible Sigmoidoscopy; Colorectal Cancer; Screening

资金

  1. UK Medical Research Council
  2. National Institute for Health Research under the Medical Research Council-National Institute for Health Research Efficacy and Mechanism Evaluation Program [09/800/08]
  3. National Institute for Health Research Health Technology Assessment Program [16/65/01]
  4. Cancer Research UK Population Research Committee Program Award [C53889/A25004]

向作者/读者索取更多资源

Higher adenoma detection rates (ADRs) in flexible sigmoidoscopy screening provide greater long-term protection against colorectal cancer (CRC) incidence and mortality.
BACKGROUND & AIMS: Detection and removal of adenomas reduces colorectal cancer (CRC) risk. The impact of adenoma detection rates (ADRs) on long-term CRC incidence and mortality is unknown. We investigated this using data from the UK Flexible Sigmoidoscopy Screening Trial. METHODS: Of 167,882 UK Flexible Sigmoidoscopy Screening Trial participants, 40,085 were in the intervention arm and underwent flexible sigmoidoscopy screening at 13 trial centers. The median follow-up time was 17 years. At each center, 1 endoscopist performed most flexible sigmoidoscopies. Multivariable logistic regression was used to classify centers into high-, intermediate-, and low-detector groups based on their main endoscopist's ADR. We calculated the incidence and mortality of distal and all-site CRC, and estimated hazard ratios (HRs) with 95% CIs using Cox regression. RESULTS: Five, 4, and 4 centers, respectively, were classified into the high-detector, intermediate-detector, and low-detector groups. The average ADRs in each respective group were 15%, 12%, and 9%. Distal CRC incidence and mortality were reduced among those screened compared with controls in all groups, and effects of screening varied significantly by detector ranking, with larger reductions in incidence and mortality seen in the high-detector group (incidence: HR, 0.34; 95% CI, 0.27-0.42; mortality: HR, 0.22, 95% CI, 0.13-0.37) than in the low-detector group (incidence: HR, 0.55; 95% CI, 0.44-0.68; mortality: HR, 0.54; 95% CI, 0.34-0.86). Similar results were observed for all-site CRC, with larger effects seen in the high-detector (incidence: HR, 0.58; 95% CI, 0.50-0.67; mortality: HR, 0.52; 95% CI, 0.39-0.69) than in the low-detector group (incidence: HR, 0.72; 95% CI, 0.61-0.85; mortality: HR, 0.68; 95% CI, 0.51-0.92), although the heterogeneity was not statistically significant. CONCLUSIONS: Higher ADRs at screening provide greater long-term protection against CRC incidence and mortality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据