4.1 Article

Association between conjunctival goblet cells and corneal resident dendritic cell density changes in new contact lens wearers

期刊

CLINICAL AND EXPERIMENTAL OPTOMETRY
卷 103, 期 6, 页码 787-791

出版社

WILEY
DOI: 10.1111/cxo.13131

关键词

conjunctival goblet cell; contact lens wear; corneal dendritic cells

资金

  1. Australian Postgraduate Award
  2. Ministry of Interior Kingdom of Saudi Arabia

向作者/读者索取更多资源

Clinical relevance Contact lens comfort is influenced by a smooth transition of changes to the ocular surface epithelium, including cellular density. Conjunctival goblet cells are known to suppress activation of dendritic cells and therefore prevent inflammatory response. Hence, monitoring goblet cell numbers during lens adaptation could potentially facilitate comfortable lens wear. Background To explore the interlink between conjunctival goblet and corneal dendritic cell density after six months of lens wear and to predict dendritic cell migration to the central cornea based on goblet cell loss in the conjunctiva as a response to contact lens wear. Methods Sixty-nine subjects who had never previously worn contact lenses were observed for six months; 46 were fitted with contact lenses and 21 served as a control group. Corneal confocal microscopy was used to quantify goblet and dendritic cell density before and after six months of daily lens wear. Symptomatic and asymptomatic groups were identified in the lens-wearing group using a combination of signs and symptoms present. Pearson's correlation was used to determine associations between the total change of cell densities after six months of lens wear. Results At baseline, there was no association between conjunctival goblet and corneal dendritic cell density (p > 0.05). After six months, there was an inverse association between the absolute change of conjunctival goblet and corneal dendritic cell density (rho = -0.34, p = 0.03) in all participants (n = 69). Dendritic cell density in the central cornea was increased by 1.5 cells/mm(2)for every decrease of 1 goblet cell/mm(2)in the conjunctiva. Conclusions After six months of wear, contact lens-induced goblet cell loss can partially predict resident corneal dendritic cell migration to the central cornea (observed as an increase in dendritic cell density). The associations between total cell density change after six months was established in wearers regardless of lens symptomatology, suggesting that cell density changes as a physiological adaptation to regulate the effect of contact lens wear on the ocular surface.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据