4.4 Article

Sensitivity Improvement in Electrochemical Immunoassays Using Antibody Immobilized Magnetic Nanoparticles with a Clean ITO Working Electrode

期刊

BIOCHIP JOURNAL
卷 14, 期 3, 页码 308-316

出版社

KOREAN BIOCHIP SOCIETY-KBCS
DOI: 10.1007/s13206-020-4309-x

关键词

Electrochemical immunosensor; Magnetic nanoparticle; Clean working electrode; Non-specific binding; Indium tin oxide electrode; Alkaline phosphatase labeling

资金

  1. Bio & Medical Technology Development Program of the National Research Foundation [NRF-2015M3A9E2028480]
  2. National Research Foundation of Korea [2015M3A9E2028480] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

We report a dramatic improvement in the detection sensitivity of electrochemical immunosensors through the use of a magnetic nanoparticle for immunoassay reactions and an ITO working electrode for measurement of the electrochemical enzymatic reaction signals. In general, electrochemical sensors developed for immunoassay require the immobilization of capture antibodies on the surface of the working electrode. Under these circumstances, the working electrode comes into direct contact with various biological samples, and unwanted non-specific binding inevitably interferes with the detection signal. Moreover, chemical surface treatment of the working electrode to immobilize capture antibodies degrades the quality of the electrochemical signals during target determination. Here, we address these issues by immobilizing capture antibodies on the surface of magnetic nanoparticles and separating the surface for measurement of electrochemical signals from the immune reactions. By avoiding direct contact with biological materials, the surface of the working electrode could not be contaminated and could be maintained clean. We also provide experimental evidence that these novel immunoassay platforms benefit from a reduction in the noise signal. Indeed, the signal-to-noise ratio, an essential characteristic of quantitative detection, could be improved by approximately 11.8-fold compared with the electrochemical immunoassay of conventional surface modification approach, while retaining an excellent coefficient of variation (<= 18%). The method was applied to the practical immunosensing for matrix met-alloproteinase-9 (MMP-9), the bladder cancer marker in the urine, and exhibited excellent performance.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据