4.7 Article

Experimental and numerical heat transfer analysis of heat-pipe-based CPU coolers and performance optimization methodology

期刊

APPLIED THERMAL ENGINEERING
卷 179, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2020.115720

关键词

Thermal management; Heat exchangers; Heat pipes; Extended surfaces; CFD simulations; Optimization methodology

资金

  1. Slovenian Research Agency (Program/Project) [P20223]

向作者/读者索取更多资源

This paper presents an experimental and numerical heat transfer analysis of heat-pipe-based CPU coolers and a performance optimization methodology. The first part of the study focuses on the performance of two commercial HP-based CPU coolers under inclination angles of 0 degrees, 90 degrees and 180 degrees. The results show that the 90 degrees orientation provides the best thermal performance. The influence of heat pipe orientation on the performance of the entire system is obscured due to the much higher thermal resistance on the air-side of the cooler. A fourfold increase in air volumetric flow rate has only a minor effect on the cooling performance enhancement with a reduction of the thermal resistance from 0.11 K W-1 to 0.074 K W-1 at the highest heating power. In the second part of the study, heat transfer numerical simulations of the finned part of a cooler were performed and validated using experimental results. The output of the simulation is a 2-D temperature field, which is used as an input for the optimization methodology based on fin effectiveness and fin efficiency. Optimizing the fin geometry by removing unnecessary material yielded a 23% increase of the fin efficiency and decreased the weight of a fin by approx. 30%, proving the usefulness of the proposed methodology, which helps reduce costs, weight and development time of finned HP-based coolers.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据