4.7 Article

Rate of CO2 adsorbent attrition induced by gas jets on perforated plate distributors in bubbling fluidized beds

期刊

ADVANCED POWDER TECHNOLOGY
卷 31, 期 10, 页码 4411-4419

出版社

ELSEVIER
DOI: 10.1016/j.apt.2020.09.015

关键词

Gas fluidized bed; Particle attrition; Abrasion; Orifice gas jet; Perforate plate distributor

资金

  1. Energy Efficiency & Resources Programs of the Korea Institute of Energy Technology Evaluation and Planning (KETEP)
  2. Ministry of Trade, Industry & Energy, Republic of Korea [20182010600530]
  3. Korea Evaluation Institute of Industrial Technology (KEIT) [20182010600530] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

Particle attrition is a major challenge when handling bulk solid materials with fluidized beds due to its ability to cause particle loss. Herein, the particle attrition induced by the gas jets on a perforated plate distributor in a bubbling fluidized bed was investigated for CO2 adsorbent particles. An attrition tube, which used air as the fluidizing gas, was used as the fluidized bed. At a constant fluidizing velocity, the initial static bed height and orifice gas velocity were considered as variables. It was confirmed that abrasion dominated the particle attrition. The trend indicating the change in the maximum size of the particles (d(pm,a)) formed by attrition followed that of the attrition rate (i.e., the formation rate of fine particles via attrition). A new stirring factor that combined the model developed by Werther and Xi with the original stirring factor adequately explained the effect of the static bed height on both the attrition rate and dpm, a when the initial static bed height was greater than the length of the orifice gas jet that penetrated the bed. The attrition rate increased linearly with the new stirring factor. However, dpm, a increased exponentially with the new stirring factor. Relationships were successfully proposed to enable the estimation of the attrition rate and dpm, a for the CO2 adsorbent particles. This study provided the evidence indicating the significance of the effect of bed height on particle attrition induced by the gas jet on the distributor. Moreover, proper models for correlating the attrition rate and the maximum size of the fine particles formed by attrition in the bubbling fluidized bed were provided. (C) 2020 The Society of Powder Technology Japan. Published by Elsevier B.V. and The Society of Powder Technology Japan. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据