4.6 Article

A Multicenter Randomized Clinical Trial of Hemodialysis Access Blood Flow Surveillance Compared to Standard of Care: The Hemodialysis Access Surveillance Evaluation (HASE) Study

期刊

KIDNEY INTERNATIONAL REPORTS
卷 5, 期 11, 页码 1937-1944

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.ekir.2020.07.034

关键词

arteriovenous access blood flow; arteriovenous access thrombosis; arteriovenous fistula; arteriovenous graft; hemodialysis access surveillance; ultrasound dilution technique

资金

  1. Transonic Systems Inc., Ithaca, NY

向作者/读者索取更多资源

Introduction: Arteriovenous (AV) access thrombosis remains 1 of the most troubling AV access-related complications affecting hemodialysis patients. It necessitates an urgent and occasionally complicated thrombectomy procedure and increases the risk of AV access loss. AV access stenosis is found in the majority of thrombosed AV accesses. The routine use of AV access surveillance for the early detection and management of stenosis to reduce the thrombosis rate remains controversial. Methods: We have conducted a multicenter, prospective, randomized clinical trial comparing the standard of care coupled with ultrasound dilution technique (UDT) flow measurement monthly surveillance with the standard of care alone. Results: We prospectively randomized 436 patients with end-stage renal disease on hemodialysis with arteriovenous fistula (AVF) or arteriovenous graft (AVG) using cluster (shift) randomization to surveillance and control groups. There were no significant differences in the baseline demographic data between the 2 groups, except for ethnicity (P = 0.017). Patients were followed on average for 15.2 months. There were significantly less per-patient thrombotic events (Poisson rate) in the surveillance group (0.12/patient) compared with the control group (0.23/patient) (P= 0.012). There was no statistically significant difference in the total number of procedures between the 2 groups, irrespective of whether thrombectomy procedures were included or excluded, and no statistically significant differences in the rate of or time to the first thrombotic event or the number of catheters placed due to thrombosis. Conclusion: The use of UDT flow measurement monthly AV access surveillance in this multicenter randomized controlled trial reduced the per-patient thrombotic events without significantly increasing the total number of angiographic procedures. Even though there is a trend, surveillance did not reduce the first thrombotic event rate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据