4.6 Article

Humidity-Sensing Properties of a BiOCl-Coated Quartz Crystal Microbalance

期刊

ACS OMEGA
卷 5, 期 30, 页码 18818-18825

出版社

AMER CHEMICAL SOC
DOI: 10.1021/acsomega.0c01946

关键词

-

资金

  1. National Natural Science Foundation of China [61871098]

向作者/读者索取更多资源

The performance of a bismuth oxychloride (BiOCl)-based quartz crystal microbalance (QCM) humidity sensor was studied using an oscillating circuit method. The BiOCl powder was prepared by a hydrolysis method. Scanning electron microscopy, X-ray diffraction, and Fourier transform infrared spectroscopy were used to characterize the BiOCl sample. Its humidity-sensing property was analyzed by combining it with a QCM at room temperature (25 degrees C). Experimental results indicated that the BiOCl-based QCM sensor showed good humidity characteristics from 11.3 to 97.3%, such as good logarithmic frequency response to humidity levels (R-2 = 0.994), fast response time (5.2 s)/recovery time (4.5 s), good reversibility, stability, repeatability, and low humidity hysteresis. In addition, the response to human nose breaths showed excellent practicability. Finally, the humidity sensing mechanism of the BiOCl-based QCM humidity sensor was discussed in detail. This work demonstrates that BiOCl is a promising candidate material for humidity detection.