Background: Sutureless and rapid-deployment aortic valve replacement (SURD-AVR) has become a prominent area of research as the medical community evaluate its place amongst other aortic valve interventions. The main advantages of SURD-AVR established to date are the reduced cross-clamp and cardiopulmonary bypass (CPB) times, as well as facilitating minimally invasive surgery in high-risk surgical patients. This current systematic review and meta-analysis, to our knowledge, is the first focusing on long-term outcomes regarding safety, efficacy and durability of SURD-AVR from available current literature. Methods: A literature search via six electronic databases was performed from their inception to November 2019. Inclusion criteria for this systematic review included survival and postoperative echocardiographic outcomes greater than five years in patients who underwent SURD-AVR with either Perceval or Intuity valves. Studies were identified and data extracted by two independent reviewers. Long-term survival outcomes were aggregated using digitized Kaplan-Meier curves where available. Results: After applying predefined inclusion and exclusion criteria, four studies were identified for review. All four studies were observational and in total reported data for 1,998 patients. Almost half (42.4%) of patients underwent SURD-AVR via full sternotomy, with almast one third (30.1%) also undergoing concomitant cardiac procedures. Aggregate overall survival rates at 1-, 2-, 3-, and 5-year follow-up were 94.9%, 91.2%, 89.0%, and 84.2%, respectively. Incidence of strokes (4.8%), severe paravalvular leaks (PVLs) (1.5%) and permanent pacemaker (PPM) insertion (8.2%) at up to 5-year follow-up were acceptable. At 5-year followup hemodynamic outcomes were also acceptable for mean pressure gradient (MPG) (range, 8.8-13.6 mmHg), peak pressure gradient (PPG) (range, 18.9-21.1 mmHg) and effective orifice area (EOA) (range, 1.5-1.8 cm(2)). Conclusions: Evaluation of the evidence reporting long-term outcomes of SURD-AVR suggests that it is a safe procedure for AVR with low rates of complications. Long-term outcomes presented in this review show that not only does SURD-AVR have acceptable survival rates, but also good hemodynamic performance at 5-year follow-up.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据