4.7 Article

Performance tests and removal mechanisms of aerated electrocoagulation in the treatment of oily wastewater

期刊

出版社

ELSEVIER
DOI: 10.1016/j.jwpe.2020.101290

关键词

Electrocoagulation; Oily wastewater; Aeration; Treatment; Removal mechanisms

资金

  1. Center for Membranes and Advanced Water Technology (CMAT) [RC2-2018-009]
  2. Khalifa University of Science and Technology in Abu Dhabi (UAE)

向作者/读者索取更多资源

Electrochemical technologies have proven to be plausible technology for the treatment of oily wastewater. This study aimed to evaluate the performance of electrocoagulation (EC) process with and without aeration for the treatment of oily wastewater. Scanning Electron Microscope (SEM) and Energy Dispersive X-ray Spectroscopy (EDS) techniques were used to analyze the sludge and the electrodes. The maximum removal of the chemical oxygen demand (COD) was higher with the aerated cells (93.3 %) than with the non-aerated cells (84 %) at 120 A m(-2) current density but at the expense of higher specific energy consumption. Electrophoresis and electro- deposition of oil were observed on both electrodes, with higher intensity on the anodes. The sludge of the aerated cell was of a gel-like structure compared to the foamy and grainy sludge obtained from the non-aerated cell. Anodes in the EC aerated cells were consumed more homogeneously, having more depositions of oil on their surfaces. Aeration helped to improve the performance of the process, highlighting the great potential of electrocoagulation processes for the treatment of oily wastewater.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据