4.7 Article

Development of a rapid GC-FID method to simultaneously determine triethylamine, diisopropylamine, and 1,1,3,3-tetramethylguanidine residues in an active pharmaceutical ingredient

期刊

JOURNAL OF PHARMACEUTICAL ANALYSIS
卷 11, 期 2, 页码 251-256

出版社

ELSEVIER
DOI: 10.1016/j.jpha.2020.06.007

关键词

GC-FID; Amines; API; Method development; Method qualification

资金

  1. AbbVie Inc.

向作者/读者索取更多资源

A rapid GC-FID method was developed to simultaneously determine residual levels of triethylamine (TEA), 1,1,3,3-tetramethylguanidine (TMG), and diisopropylamine (DIPA) in the synthetic route of an active pharmaceutical ingredient (API). The method involved evaluating GC columns with various stationary phases to achieve optimal peak shape and reproducibility, along with screening various inlet liners to improve sensitivity. The study also identified a new reaction mechanism involving TMG, leading to a more accurate final detection method.
A rapid GC-FID method was developed to simultaneously determine residual levels of triethylamine (TEA), 1,1,3,3-tetramethylguanidine (TMG), and diisopropylamine (DIPA) in the synthetic route of an active pharmaceutical ingredient (API). Due to the severe absorption of amines on GC stationary phases, GC columns with various stationary phases were evaluated for optimal peak shape and reproducibility. The final conditions used the Agilent CP-Volamine column to resolve the three amines in 12 min. Various inlet liners were also screened to further improve the sensitivity of the analysis. The Restek Siltek? liner was selected to achieve the desired detectability for the method. The quantitation limits were 4, 3, and 4 mg/mL for TEA, DIPA, and TMG in the presence of API, respectively. All three amines showed good linearity (r > 0.999) and recoveries (> 90%) over the concentration range of 3 to 16 mg/mL. The testing of residual amines was initially performed at the penultimate stage of the synthesis. However, this work demonstrates that TMG can act as a proton sponge to react with salicylic acid, the counter ion of the penultimate, to form a volatile component that elutes at a different retention time. Consequently, in the final method, these three amines were monitored in the final API to circumvent the matrix interference. Key parameters of the method were qualified per method validation requirements in ICH guidelines. The method was successfully applied for batch testing during development and implemented as an inprocess control procedure at manufacturing sites. (c) 2020 Xi'an Jiaotong University. Production and hosting by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据