4.7 Article

A Low-Harmonic Control Method of Bidirectional Three-Phase Z-Source Converters for Vehicle-to-Grid Applications

期刊

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TTE.2020.2984420

关键词

Bidirectional converter; closed-loop control; shoot-through states; voltage harmonics; Z-source converter

资金

  1. Research Grants Council of the Hong Kong Special Administrative Region (HKSAR) Government [R5020-18]
  2. Innovation and Technology Commission of the HKSAR Government [K-BBY1]

向作者/读者索取更多资源

Three-phase Z-source inverters provide a solution of voltage boosting by a single-stage topology. They are also capable of bidirectional operation as rectifiers, thus have great potential for applications in the field of transportation electrification such as vehicle-to-grid (V2G) chargers. In this article, three new modulation schemes for three-phase Z-source converters are proposed and investigated. The best performed one is further developed to a closed-loop proportional-integral (PI) control method. Although the voltage conversion ratio is flexible, the output voltage total harmonics distortion (THD) is below 3% within the voltage ratio range 0.5-2.5. The effectiveness of the proposed method has been fully validated in MATLAB/Simulink simulations and RT-Lab hardware-in-loop (HIL) experiments based on the real-time simulator OPAL-RT OP4510. Compared to existing control methods, the proposed one performs better with reduced harmonics, flexible voltage gain, and simpler control algorithm.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据