4.7 Review

Bioactive Surfaces vs. Conventional Surfaces in Titanium Dental Implants: A Comparative Systematic Review

期刊

JOURNAL OF CLINICAL MEDICINE
卷 9, 期 7, 页码 -

出版社

MDPI
DOI: 10.3390/jcm9072047

关键词

Ti dental implants; bioactive surfaces; biofunctionalized surfaces; osseointegration

向作者/读者索取更多资源

Animal studies and the scarce clinical trials available that have been conducted suggest that bioactive surfaces on dental implants could improve the osseointegration of such implants. The purpose of this systematic review was to compare the effectiveness of osseointegration of titanium (Ti) dental implants using bioactive surfaces with that of Ti implants using conventional surfaces such as sandblasted large-grit acid-etched (SLA) or similar surfaces. Applying the guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, the MEDLINE, PubMed Central and Web of Science databases were searched for scientific articles in April 2020. The keywords used were dental implants, bioactive surfaces, biofunctionalized surfaces, and osseointegration, according to the question: Do bioactive dental implant surfaces have greater osseointegration capacity compared with conventional implant surfaces? Risk of bias was assessed using the Cochrane Collaboration tool. 128 studies were identified, of which only 30 met the inclusion criteria: 3 clinical trials and 27 animal studies. The average STROBE (STrengthening the Reporting of OBservational studies in Epidemiology) and ARRIVE (Animal Research: Reporting of In Vivo Experiments) scores were 15.13 +/- 2.08 and 17.7 +/- 1.4, respectively. Implant stability quotient (ISQ) was reported in 3 studies; removal torque test (RTT)-in 1 study; intraoral periapical X-ray and microcomputed tomography radiological evaluation (RE)-in 4 studies; shear force (SF)-in 1 study; bone-to-implant contact (BIC)-in 12 studies; and BIC and bone area (BA) jointly-in 5 studies. All animal studies reported better bone-to-implant contact surface for bioactive surfaces as compared to control implants with a statistical significance ofp< 0.05. Regarding the bioactive surfaces investigated, the best results were yielded by the one where mechanical and chemical treatment methods of the Ti surfaces were combined. Hydroxyapatite (HA) and calcium-phosphate (Ca-Ph) were the most frequently used bioactive surfaces. According to the results of this systematic review, certain bioactive surfaces have a positive effect on osseointegration, although certain coating biomolecules seem to influence early peri-implant bone formation. Further and more in-depth research in this field is required to reduce the time needed for osseointegration of dental implants.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据