4.7 Article

Near-surface flame structure characterization of simplified ammonium perchlorate/hydroxyl-terminated polybutadiene compositions

期刊

COMBUSTION AND FLAME
卷 164, 期 -, 页码 201-211

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.combustflame.2015.11.017

关键词

Ammonium perchlorate; Hydroxyl-terminated polybutadiene; Planar laser-induced fluorescence; Burning rate; Flame structure; Composite propellant

资金

  1. NSF GRFP [1147384]
  2. AFOSR MURI [FA9550-13-1-0004]
  3. Division Of Graduate Education
  4. Direct For Education and Human Resources [1147384] Funding Source: National Science Foundation

向作者/读者索取更多资源

Simplified model propellant configurations, such as monomodal propellants, can be valuable in the development and validation of predictive numerical tools. These idealized experiments also yield insight into the effect of diffusion length scales on combustion, but comprehensive data covering a large range of diffusional length scales do not currently exist. Here, monomodal propellants with ammonium perchlorate (AP) particle sizes under 800 mu m and AP pellets ported and filled with hydroxyl-terminated polybutadiene (HTPB) were used to systematically study the effect of diffusion length scales, or AP equivalent particle sizes) of up to 4.1 mm on flame structure. In general, burning rates increased with pressure and decreasing particle size, as expected. Burning rates for samples with particle sizes greater than 400 mu m converged with AP monopropellant burning rate data above approximately 2 MPa, the AP low-pressure deflagration limit (LPDL). For a given pressure above the LPDL, burning rates eventually became constant for both increasing and decreasing particle sizes. Conversely, for a given pressure below the LPDL burning rate was shown to be a function of particle diameter. Flame structures above the composite propellants were observed using 5 kHz OH planar laser-induced fluorescence (PLIF). The transient flames were underventilated (jet-like) over the AP particles at 1 atm while lifted, inverted, and overventilated at 5 atm. Distinct diffusion flame structures were observed visually above the ported samples at 1 atm. Very luminous flames were observed at the interface between the AP and binder. The effect of strain rate on sample combustion was examined using an opposed flow burner; at 1 atm, sample burning rate was not affected by strain rate. At the largest strain rate, the sample self extinguished after igniter shutoff, indicating that secondary diffusion flames are important in the opposed flow configuration. (C) 2015 The Combustion Institute. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据