4.6 Article

Parametric Sensitivity Analysis for the Industrial Case of O-Xylene Oxidation to Phthalic Anhydride in a Packed Bed Catalytic Reactor

期刊

CATALYSTS
卷 10, 期 6, 页码 -

出版社

MDPI
DOI: 10.3390/catal10060626

关键词

parametric sensitivity analysis; o-xylene oxidation; packed bed tubular reactor; safe operation conditions

向作者/读者索取更多资源

The operation of packed bed tubular reactors, for exothermic catalytic reactions, presents special challenges provoked by hotspot development. Their potential safety risk can be assessed using different mathematical methodologies, among them, the so-called parametric sensitivity analysis (PSA). This study deals with the identification of safe operational conditions (e.g., feed temperature conditions) for the catalytic oxidation of o-xylene. Three different reaction networks, with different degrees of complexity, were analyzed. Thus, the critical values of the operating parameters, allowing us to define run-away and stable operation conditions, were provided for different reactive configurations. The obtained results were compared with the data reported by various authors who used similar reaction rate laws. The purpose of the present study is to illustrate the peculiarities of the PSA and its application for the design, analysis, and operation of o-xylene multitubular catalytic reactor.