4.5 Article

Compound parabolic solar collector - Performance evaluation as per standard test method and actual field conditions for industrial process heat application in Indian context

期刊

ENERGY FOR SUSTAINABLE DEVELOPMENT
卷 57, 期 -, 页码 98-108

出版社

ELSEVIER
DOI: 10.1016/j.esd.2020.06.001

关键词

Non-Imaging concentrator; CPC; Industrial Process Heat; Thermal performance; IS 16648 (Part-5); Boiler feed water heating

资金

  1. National Test Facility for Concentrating Solar Thermal Technologies under the Ministry of New and Renewable Energy, Government of India
  2. United Nations' Development Program on Concentrated Solar Heat at School of Energy Studies, Savitribai Phule Pune University, Pune, India

向作者/读者索取更多资源

Industrial process heating has been identified as a potential field for solar thermal applications. In this paper, a comparative study was carried out on the performance of an individual solar collector under laboratory condi-tions and performance of the collector array under field condition. Compound Parabolic Concentrator (CPC) has been used as a solar collector for the application of boiler feed water preheating. The characterization of CPC has been done in liquid phase with water as a working fluid as per the standard, IS 16648 (Part-5):2017. The optical efficiency of the CPC is found to be 64.8% under standard test conditions. In the field, total 200 number of CPCs, each having 3 m(2) area, were installed. The performance monitoring and evaluation of the actual instal-lation was carried out over a period of 10 months. The system was designed to supply average 448,500 kWh-Thermal/year, saving the equivalent amount of fossil fuel. The comparative study of the performance of CPC collector under standard conditions and actual operating conditions in the field shows significant variation. The average variation in the performance was about 9% with a maximum variation of 14.7%. The major reasons behind the lower performance output than expected, attribute to the heat losses through the collector manifold and piping (3.9%), soiling of reflector and absorber of CPC (1.72%), uncertainties of instruments (1.49%) and other unaccounted losses like dislocation of the evacuated tubes from the original position, loss of vacuum through evacuated tubes, shadow effect, heat utilization pattern etc. (1.89%), which should be considered while designing the solar field to meet the required output. (C) 2020 International Energy Initiative. Published by Elsevier Inc. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据