4.6 Article

Diffusion-Weighted Imaging (DWI) derived from PET/MRI for lymph node assessment in patients with Head and Neck Squamous Cell Carcinoma (HNSCC)

期刊

CANCER IMAGING
卷 20, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s40644-020-00334-x

关键词

MRI; DWI; ADC; HNSCC; Metastasis; Benign; Lymph nodes

向作者/读者索取更多资源

Background: To determine the usefulness of Diffusion Weighted Imaging (DWI) derived from PET/MRI in discriminating normal from metastatic lymph nodes and the correlation between the metastatic lymph nodes with the grade and the localization of the primary tumor. Methods: Retrospective study of 90 lymph nodes from 90 subjects; 65 patients who had proven histopathological metastatic lymph nodes from (HNSCC) who had undergone F-18- PET/MRI for clinical staging and assessment and twenty-five lymph nodes were chosen from 25 healthy subjects. Apparent Diffusion Coefficient (ADC) map was generated from DWI withbvalues (0 and 800 s/mm(2)). ADC values of the metastatic lymph nodes were calculated and compared to the normal lymph nodes ADC values, ROC was used to determine the best cut-off values to differentiate between the two group. Metastatic lymph nodes ADC mean values were compared to primary tumor grade and localization. Results: ADC mean value of the metastatic lymph nodes in the overall sample (0.899 +/- 0.98*10(- 3) mm(2)/sec) was significantly lower than the normal lymph nodes' ADCmean value (1.267 +/- 0.88*10(- 3) mm(2)/sec); (P = 0.001). The area under the curve (AUC) was 98.3%, sensitivity and specificity were 92.3 and 98.6%, respectively, when using a threshold value of (1.138 +/- 0.75*10(- 3) mm(2)/sec) to differentiate between both groups. Significant difference was found between metastatic lymph nodes (short-axis diameter < 10 mm), ADCmean (0.898 +/- 0.72*10(- 3) mm(2)/sec), and the benign lymph nodes ADCmean, (P = 0.001). No significant difference was found between ADCmean of the metastatic lymph nodes < 10 mm and the metastatic lymph nodes > 10 mm, ADCmean (0.899 +/- 0.89*10(- 3) mm(2)/sec), (P = 0.967). No significant differences were found between metastatic lymph nodes ADCmean values and different primary tumor grades or different primary tumor localization, (P > 0.05). Conclusion: DWI-ADC is an effective and efficient imaging technique in differentiating between normal and malignant lymph nodes, and might be helpful to discriminate sub-centimeters lymph nodes.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据