4.7 Article

Photoacoustic method for real-time assessment of salt content in aqueous solutions

期刊

TALANTA
卷 222, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.talanta.2020.121497

关键词

Full factorial design; Injectable drug products; Process analytical technologies (PAT); Photoacoustics; Real-time control

资金

  1. FCT (Fundacao para a Ciencia e Tecnologia, Portugal)
  2. Laboratorios Basi [PD/BDE/142962/2018]
  3. FCT [UIDB/QUI/00313/2020]
  4. [POCI-01-0145-FEDER-027996]

向作者/读者索取更多资源

The Food and Drug Administration established foundations for the application of Process Analytical Technologies (PAT) in real-time control of drug manufacturing process in 2004, mainly focused on solid formulations. To expand the application of PAT principles to injectable drug products, the development of appropriate manufacturing process control tools is necessary. Photoacoustics, a non-invasive technique, shows potential for real-time control of the manufacturing process of injectable drug products.
In 2004, the Food and Drug Administration established the foundations for the application of process analytical technologies (PAT) in real-time control of the drug manufacturing process, where progress has been essentially directed to solid formulations. In order to enlarge the application of PAT principles to injectable drug products, the development of appropriate manufacturing process control tools is mandatory. Photoacoustics is a non-invasive technique with the potential for application in real-time control of the manufacturing process of injectable drug products. Herein, we applied a photoacoustic method for the determination of the concentration of salts (sodium chloride) in mono-salt formulations by measuring the changes induced in the speed of sound by density changes. This method was explored using two modes of generating the photoacoustic wave and two detectors with central frequencies of 10 MHz and 100 MHz. The results were analyzed using a 2(k) full-factorial design, considering the generation mode and detection as independent variables. The optimized method was subsequently validated according to the International Council for Harmonisation (ICH) standards. The method showed good linearity, precision, and accuracy, with a lower limit of quantification of 0.05% (w/v) of NaCl and a limit of detection of 0.02% (w/v) of NaCl. Due to its simplicity and high throughput, this method has potential applicability as PAT in the manufacturing of injectable drug products.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据