4.6 Article

A comparative study on thermoelectric performances and energy savings of double-skin photovoltaic windows in cold regions of China

期刊

SOLAR ENERGY
卷 206, 期 -, 页码 464-472

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.solener.2020.05.094

关键词

DS-STPV; Ventilation modes; Thermoelectric performance; Net electricity use; Energy saving potential

资金

  1. National Natural Science Foundation of China [51808372]
  2. National Key Research and Development Program of China [2018YFD1100701-05]
  3. Key Research and Development (R&D) Projects of Shanxi Province [201903D121037, 201803D121105]
  4. Opening Funds of State Key Laboratory of Building Safety and Built Environment [BSBE2018-02]
  5. Application Foundation Research Plan of Shanxi Province [201801D221348]
  6. Scientific and Technological Innovation Programs of Higher Education Institutions in Shanxi [201802046]
  7. China Postdoctoral Science Foundation [2017M611200]
  8. National Engineering Research Center of Building Technology [BSBE2018-02]

向作者/读者索取更多资源

The use of double-skin semitransparent photovoltaic (DS-STPV) windows is well recognized as an efficient and effective approach for enhancing the building energy performance. However, despite many studies in relation to the technology have been reported so far, there are few investigations focusing on its use in cold regions. In this study, experimental measurement data for a DS-STPV window in terms of power generation and surface temperature were compared with those obtained from EnergyPlus simulations. The measured and simulated results agreed well, which confirmed the reliability of the simulation methodology adopted. On this basis, the energy performance of DS-STPV windows with non-ventilated, inner loop, and air supply ventilation modes was analyzed by simulations performed for winter conditions in cold regions. The results showed that as compared with the other two ventilation modes, the use of air supply DS-STPV windows is capable of reducing the building net electricity use by 18.5% and 20.2%, respectively. Further, an optimal control strategy for DS-STPV windows employed in cold regions was also proposed. It was found that with the use of the proposed strategy, the building net electricity use can be effectively reduced by 3.5% and 12.3%, respectively. Relevant findings of the present study provide an insight into optimal design and control of the DS-STPV windows employed in cold regions. Further, the results presented and the simulation methodology established will also be useful for further development of the technology for energy savings and emission reductions.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据