4.2 Article

Characterization and Treatment of Medical Laboratory Wastewater by Ozonation: Optimization of Toxicity Removal by Central Composite Design

期刊

OZONE-SCIENCE & ENGINEERING
卷 43, 期 3, 页码 213-227

出版社

TAYLOR & FRANCIS INC
DOI: 10.1080/01919512.2020.1794794

关键词

Ozonation; medical laboratory wastewater; characterization; toxicity; central composite design

资金

  1. Ministry of Environment and Urbanization
  2. Yildiz Technical University-the Scientific Research Projects Coordination Unit [FDK-2018-3426]

向作者/读者索取更多资源

The study found that medical laboratory wastewaters have highly toxic properties, and ozone treatment is an effective option for removing COD, BOD5, AOX, and TU from MLW.
This study performed a long-term characterization of medical laboratory wastewaters (MLWs) arising from diagnosis and examination units. The results indicated that the MLWs may be assessed as strong domestic wastewater and also have highly toxic properties. Furthermore, statistical optimization of toxicity removal through ozonation was investigated using the central composite design. COD, BOD5, AOX, and Toxicity unit (TU) removals were determined to be 50.6%, 43.2%, 48.9%, and 99.9%, respectively. The TU value of the MLW decreased from 163 to 0.16. The results of the study indicated that the ozonation process is an effective treatment option for COD, BOD5, AOX, and TU removal from MLW.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。