4.6 Article

A prospective parallel design study testing non-inferiority of customized oral stents made using 3D printing or manually fabricated methods

期刊

ORAL ONCOLOGY
卷 106, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.oraloncology.2020.104665

关键词

3D printing; Head and neck cancer; Oral stent; Radiation therapy

资金

  1. Andrew Sabin Family Fellowship
  2. Sheikh Ahmed Center for Pancreatic Cancer Research
  3. University of Texas MD Anderson Cancer Center
  4. Center of Advanced Biomedical Imaging, Project Purple
  5. Cancer Center Support (Core) Grant from the National Cancer Institute [CA016672]
  6. NIH [U54CA210181-01, U54CA143837, U01CA196403, 1R01DE025248-01/R56DE025248-01, 1R01CA214825-01, 1R01CA218148-01, P30CA016672, P50 CA097007-10]
  7. Sabin Family Foundation
  8. National Science Foundation (NSF) [NSF 1557679]
  9. Elekta AB

向作者/读者索取更多资源

Background and purpose: Customized mouth-opening-tongue-depressing-stents (MOTDs) may reduce toxicity in patients with head and neck cancers (HNC) receiving radiotherapy (RT). However, making MOTDs requires substantial resources, which limits their utilization. Previously, we described a workflow for fabricating customized 3D-printed MOTDs. This study reports the results of a prospective trial testing the non-inferiority of 3D-printed to standard and commercially-available (TruGuard) MOTDs as measured by patient reported outcomes (PROs). Materials and methods: PROs were collected at 3 time points: (t1) simulation, (t2) prior to RT, (t3) between fractions 15-25 of RT. Study participants received a 3D-printed MOTDs (t1, t2, t3), a wax-pattern (t1), an acrylic-MOTDs (t2, t3) and an optional TruGuard (t1, t2, t3). Patients inserted the stents for 5-10 min and completed a PRO-questionnaire covering ease-of-insertion and removal, gagging, jaw-pain, roughness and stability. Inter-incisal opening and tongue-displacement were recorded. With 39 patients, we estimated 90% power to detect a non-inferiority margin of 2 at a significance level of 0.025. Matched pairs and t-test were used for statistics. Results: 41 patients were evaluable. The 3D-printed MOTDs achieved a significantly better overall PRO score compared to the wax-stent (p = 0.0007) and standard-stent (p = 0.0002), but was not significantly different from the TruGuard (p = 0.41). There was no difference between 3D-printed and standard MOTDs in terms of inter-incisal opening (p = 0.4) and position reproducibility (p = 0.98). The average 3D-printed MOTDs turnaround time was 8 vs 48 h for the standard-stent. Conclusions: 3D-printed stents demonstrated non-inferior PROs compared to TruGuard and standard-stents. Our 3D-printing process may expand utilization of MOTDs.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据